MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/030006051204000538

Медицинская библиотека · The Journal of international medical research · 2012

Levonorgestrel-releasing intrauterine device is an efficacious contraceptive for women with leiomyoma.

Xie Z-W, Zhang Y-N, Wan S, Xu W-Z, Chen J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the efficacy of a levonorgestrel-releasing intrauterine device (LNG-IUD) as contraception for women with uterine leiomyoma.

METHODS

Thirty women with uterine leiomyoma requiring contraception were enrolled and had a LNG-IUD inserted. Menstrual blood volume (assessed by a pictorial blood loss assessment chart [PBAC]), haemoglobin concentration, volume of uterus and leiomyoma were determined before and after LNG-IUD insertion.

RESULTS

The median (range) PBAC score was 145.0 (60.0-232.0) before LNG-IUD insertion, which significantly decreased to 44.0 (0.0-99.0) and 36.0 (0.0-90.0) after 6 and 12 months of LNG-IUD use, respectively. Prior to LNG-IUD insertion, the median haemoglobin concentration in patients with anaemia was 100.0 (69.0-109.0) g/l and this increased significantly after 6 and 12 months of LNG-IUD use, to 117.5 (101.0-131.0) g/l and 119.5 (108.0-135.0) g/l, respectively. There were no significant changes in uterine or leiomyoma volumes. No patient became pregnant and there were no severe side-effects; one IUD was expulsed.

CONCLUSION

The LNG-IUD may be a safe and effective contraceptive for women of reproductive age with uterine leiomyoma.

Для цитирования: Xie Z-W, Zhang Y-N, Wan S, Xu W-Z, Chen J. Levonorgestrel-releasing intrauterine device is an efficacious contraceptive for women with leiomyoma.. The Journal of international medical research. 2012. DOI: 10.1177/030006051204000538.