BACKGROUND

This study evaluated the accuracy of blow out fracture reduction using 3D-printed rapid prototyping (RP) skull modeling.

PATIENTS AND

METHODS

Retrospective review was performed for 82 patients who underwent post-traumatic orbital wall fracture reduction between 2012 and 2014. Patients were divided into two groups according to the use of 3D-printed RP skull model reproduced by mirroring technique, onto which a titanium mesh was anatomically molded. Using computed tomographic scans, the areas of pre- and post-operative orbital wall defect, the layout angles of the titanium mesh, and the gap lengths between the implant and fracture margin were compared between the two groups.

RESULTS

Of the 82 patients identified, 46 and 36 were diagnosed with medial and inferior orbital wall fractures, respectively. Bone defect area of the RP group was significantly reduced in comparison with that of the conventional group (8.03 ± 3.5% versus 18.7 ± 15.41% for medial wall fractures, 7.14 ± 5.74% versus 12.8 ± 4.92% for inferior wall fractures, respectively, p < 0.01). Satisfactory results were achieved regarding the layout angles and the gap lengths, presenting significantly reduced values in the RP group compared to that in the conventional group (p < 0.01).

CONCLUSIONS

More accurate restoration of traumatic orbital wall fractures can be achieved using patient-specific 3D-printed RP skull models.

Для цитирования: Kim Young Chul, Jeong Woo Shik, Park Tae-Kyung, Choi Jong Woo, Koh Kyung S, Oh Tae Suk. The accuracy of patient specific implant prebented with 3D-printed rapid prototype model for orbital wall reconstruction.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2017. DOI: 10.1016/j.jcms.2017.03.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.