MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fcvm.2023.1265550

Медицинская библиотека · Frontiers in cardiovascular medicine · 2023

Comparison of intracardiac vs. transesophageal echocardiography for "one-stop" procedures of combined radiofrequency catheter ablation and left atrial appendage closure with the Watchman device in the treatment of atrial fibrillation.

Shang Xining, Sun Mingyu, Wang Zulu, Jin Zhiqing, Liang Ming

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVE

This study aimed to assess the efficacy and safety of "one-stop" procedures that combined radiofrequency catheter ablation and left atrial appendage closure (LAAC) with the Watchman device under the guidance of intracardiac echocardiography (ICE) vs. transesophageal echocardiography (TEE) in patients with atrial fibrillation.

METHODS AND

RESULTS

In this study, we prospectively enrolled patients who underwent "one-stop" procedures under the guidance of ICE (n = 193, 109 men, 65.02 ± 8.47 years) or TEE (n = 109, 69 men, 64.23 ± 7.75 years) between January 2021 and October 2022. Intraprocedural thrombus formation in the left atrial appendage (LAA) was observed in 3 (1.46%) patients in the ICE group and 15 (11.63%) patients in the TEE group (P < 0.05) before LAAC. Total fluoroscopy time and dose in the ICE group were less than those in the TEE group. The total "one-stop" turnaround time and LAAC procedure time in the ICE group were significantly shorter than those in the TEE group (P < 0.05). Postoperative esophagus discomfort, nausea and vomiting, and hypotension were more often seen in the TEE group (P < 0.001). There was no significant difference in matched cases between ICE and fluoroscopy measurements (P = 0.082). The TEE results related to LAAC and clinical events were similar between the two groups during the follow-up (P > 0.05).

CONCLUSION

The ICE-guided "one-stop" procedure was safe and feasible with less radiation exposure, shorter turnaround time, and fewer complications and intraoperative thrombus formations than the TEE group. ICE offered accurate measurements in the LAA dimension during LAAC. Echocardiography during the "one-stop" procedures was necessary to rule out the intraoperative thrombus.

Для цитирования: Shang Xining, Sun Mingyu, Wang Zulu, Jin Zhiqing, Liang Ming. Comparison of intracardiac vs. transesophageal echocardiography for "one-stop" procedures of combined radiofrequency catheter ablation and left atrial appendage closure with the Watchman device in the treatment of atrial fibrillation.. Frontiers in cardiovascular medicine. 2023. DOI: 10.3389/fcvm.2023.1265550.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.