MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.mri.2011.02.023

Медицинская библиотека · Magnetic resonance imaging · 2011

Prospective image registration for automated scan prescription of follow-up knee images in quantitative studies.

Goldenstein Janet, Schooler Joseph, Crane Jason C, Ozhinsky Eugene, Pialat Jean-Baptiste, Carballido-Gamio Julio, Majumdar Sharmila

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Consistent scan prescription for MRI of the knee is very important for accurate comparison of images in a longitudinal study. However, consistent scan region selection is difficult due to the complexity of the knee joint. We propose a novel method for registering knee images using a mutual information registration algorithm to align images in a baseline and follow-up exam. The output of the registration algorithm, three translations and three Euler angles, is then used to redefine the region to be imaged and acquire an identical oblique imaging volume in the follow-up exam as in the baseline. This algorithm is robust to articulation of the knee and anatomical abnormalities due to disease (e.g., osteophytes). The registration method is performed only on the distal femur and is not affected by the proximal tibia or soft tissues. We have incorporated this approach in a clinical MR system and have demonstrated its utility in automatically obtaining consistent scan regions between baseline and follow-up examinations, thus improving the precision of quantitative evaluation of cartilage. Results show an improvement with prospective registration in the coefficient of variation for cartilage thickness, cartilage volume and T2 relaxation measurements.

Для цитирования: Goldenstein Janet, Schooler Joseph, Crane Jason C, Ozhinsky Eugene, Pialat Jean-Baptiste, Carballido-Gamio Julio, Majumdar Sharmila. Prospective image registration for automated scan prescription of follow-up knee images in quantitative studies.. Magnetic resonance imaging. 2011. DOI: 10.1016/j.mri.2011.02.023.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.