MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2337/dc20-2878

Медицинская библиотека · Diabetes care · 2021

A Randomized, Open-Label Comparison of Once-Weekly Insulin Icodec Titration Strategies Versus Once-Daily Insulin Glargine U100.

Lingvay Ildiko, Buse John B, Franek Edward, Hansen Melissa V, Koefoed Mette M, Mathieu Chantal, Pettus Jeremy, Stachlewska Karolina, Rosenstock Julio

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Insulin icodec is a novel once-weekly basal insulin analog. This trial investigated the efficacy and safety of icodec using different once-weekly titration algorithms.

RESEARCH DESIGN AND

METHODS

This was a phase 2, randomized, open-label, 16-week, treat-to-target study. Insulin-naive adults (n = 205) with type 2 diabetes and HbA1c 7-10% while treated with oral glucose-lowering medications initiated once-weekly icodec titrations A (prebreakfast self-measured blood glucose target 80-130 mg/dL; adjustment ±21 units/week; n = 51), B (80-130 mg/dL; ±28 units/week; n = 51), or C (70-108 mg/dL; ±28 units/week; n = 52), or once-daily insulin glargine 100 units/mL (IGlar U100) (80-130 mg/dL; ±4 units/day; n = 51), all titrated weekly. Percentage of time in range (TIR) (70-180 mg/dL) during weeks 15 and 16 was measured using continuous glucose monitoring.

RESULTS

TIR improved from baseline (means: A, 57.0%; B, 55.2%; C, 51.0%; IGlar U100, 55.3%) to weeks 15 and 16 (estimated mean: A, 76.6%; B, 83.0%; C, 80.9%; IGlar U100, 75.9%). TIR was greater for titration B than for IGlar U100 (estimated treatment difference 7.08%-points; 95% CI 2.12 to 12.04; P = 0.005). No unexpected safety signals were observed. Level 2 hypoglycemia (<54 mg/dL) was low in all groups (0.05, 0.15, 0.38, 0.00 events per patient-year of exposure for icodec titrations A, B, and C and IGlar U100, respectively), with no episodes of severe hypoglycemia.

CONCLUSIONS

Once-weekly icodec was efficacious and well tolerated across all three titration algorithms investigated. The results for icodec titration A (80-130 mg/dL; ±21 units/week) displayed the best balance between glycemic control and risk of hypoglycemia.

Для цитирования: Lingvay Ildiko, Buse John B, Franek Edward, Hansen Melissa V, Koefoed Mette M, Mathieu Chantal, Pettus Jeremy, Stachlewska Karolina, Rosenstock Julio. A Randomized, Open-Label Comparison of Once-Weekly Insulin Icodec Titration Strategies Versus Once-Daily Insulin Glargine U100.. Diabetes care. 2021. DOI: 10.2337/dc20-2878.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.