MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5114/jcb.2023.134174

Медицинская библиотека · Journal of contemporary brachytherapy · 2023

Hydrogel spacer injection to the meso-sigmoid to protect the sigmoid colon in cervical cancer brachytherapy: A technical report.

Sakuramachi Madoka, Murakami Naoya, Nagao Ayaka, Kojima Kanako, Miyata Yusaku, Kashihara Tairo, Kaneda Tomoya, Takahashi Kana, Inaba Koji, Okuma Kae, Nakayama Yuko, Okamoto Hiroyuki, Ishikawa Mitsuya, Igaki Hiroshi

СтатьяПеревод в очереди

Аннотация

PURPOSE: The use of a hydrogel spacer inserted into recto-vaginal fossa is a valuable strategy to mitigate radiation exposure to the rectum during radiation therapy for female pelvic malignancies. However, when the sigmoid colon is in proximity to the cervix, radiation exposure to the sigmoid colon cannot be adequately mitigated with a hydrogel spacer injected into the recto-vaginal fossa. Here, we presented a case, in which a hydrogel spacer was injected into the meso-sigmoid to protect the sigmoid colon.

MATERIAL AND

METHODS

A 73-year-old female diagnosed with T3b stage IIIC2r uterine cervical cancer (FIGO 2018) underwent high-dose-rate interstitial brachytherapy consisting of 24 Gy in 4 fractions, following concurrent chemoradiotherapy with external beam radiation therapy of 50 Gy in 25 fractions of whole pelvic radiation therapy. In the initial brachytherapy, the sigmoid colon was in close contact with the uterine cervix. In the second brachytherapy, attempts to create a space between the sigmoid colon and uterine cervix using injected artificial ascites were unsuccessful due to rapid absorption of fluid. In the third and fourth brachytherapy fractions, 5 mL of hydrogel was injected into the meso-sigmoid through a pouch of Douglas under trans-rectal ultrasonography guidance. Dose ratio of sigmoid colon D2cc and high-risk clinical target volume (HR-CTV) D90 of each brachytherapy were evaluated.

RESULTS

Dose ratio of the sigmoid colon D2cc to HR-CTV D90 was 1.03, 0.43, 0.56, and 0.47 in each respective brachytherapy session, indicating dose escalation to HR-CTV whilst achieving acceptable sigmoid dose with hydrogel spacer injected into the meso-sigmoid.

CONCLUSIONS

The dose ratio of the sigmoid colon to HR-CTV D90 was decreased by introducing a hydrogel spacer into the meso-sigmoid. In cases where the sigmoid colon is in proximity to the cervical tumor, this novel technique can be considered to achieve better clinical outcomes.

Для цитирования: Sakuramachi Madoka, Murakami Naoya, Nagao Ayaka, Kojima Kanako, Miyata Yusaku, Kashihara Tairo, Kaneda Tomoya, Takahashi Kana, Inaba Koji, Okuma Kae, Nakayama Yuko, Okamoto Hiroyuki, Ishikawa Mitsuya, Igaki Hiroshi. Hydrogel spacer injection to the meso-sigmoid to protect the sigmoid colon in cervical cancer brachytherapy: A technical report.. Journal of contemporary brachytherapy. 2023. DOI: 10.5114/jcb.2023.134174.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.