The role of color Doppler imaging in the diagnosis of polycystic ovary syndrome.

Battaglia C, Artini P G, D'Ambrogio G, Genazzani A D, Genazzani A R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Our purpose was to evaluate whether intraovarian and uterine blood flow variations are associated with clinical, ultrasonographic, and endocrine polycystic ovary syndrome findings.

STUDY

DESIGN

Thirty-two hirsute, oligomenorrheic patients and 18 volunteer women underwent in the early follicular phase ultrasonographic evaluation of ovarian volume, echodensity, and follicle number; transvaginal color Doppler measurement of the uterine and intraovarian vessel variations; and radioimmunologic dosage of luteinizing hormone, follicle-stimulating hormone, estradiol, progesterone, testosterone, androstenedione, and other hormonal compartments.

RESULTS

In the patients with polycystic ovary syndrome (increased luteinizing hormone/follicle-stimulating hormone ratio, elevated androstenedione levels, high number of subcapsular follicles by ultrasonography-augmented ovarian volume and echodensity) (n = 22) we observed, at Doppler analysis, significantly elevated uterine artery pulsatility index values associated with a typical low resistance index of stromal ovary vascularization. The pulsatility index was positively correlated with the luteinizing hormone/follicle-stimulating hormone ratio, and the resistance index was negatively correlated. The elevated uterine artery resistance was correlated with androstenedione levels.

CONCLUSION

Doppler analysis can be a valuable additional tool for the diagnosis of polycystic ovary syndrome.

Для цитирования: Battaglia C, Artini P G, D'Ambrogio G, Genazzani A D, Genazzani A R. The role of color Doppler imaging in the diagnosis of polycystic ovary syndrome.. American journal of obstetrics and gynecology. 1995. DOI: 10.1016/0002-9378(95)90094-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.