MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.apmr.2010.10.035

Медицинская библиотека · Archives of physical medicine and rehabilitation · 2011

Single blind, prospective, randomized controlled trial comparing dorsal aluminum and custom thermoplastic splints to stack splint for acute mallet finger.

O'Brien Lisa J, Bailey Michael J

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To compare Stack, dorsal, and custom splinting techniques in people with acute type 1a or b mallet finger.

DESIGN

Multi-center randomized controlled trial.

SETTING

Outpatient hand therapy clinics (2 public hospitals and 1 private clinic).

PARTICIPANTS

Patients (N=64) with acute type 1a or b mallet finger.

INTERVENTIONS: Prefabricated Stack splint (control), dorsal padded aluminum splint, or custom-made thermoplastic thimble splint. All were worn for 8 weeks continuously, with a 4 week graduated withdrawal and exercise program.

MAIN OUTCOME MEASURES: The primary outcome was extensor lag at 12 and 20 weeks. Secondary outcomes were incidence of treatment failure, complications, range of motion of the distal interphalangeal joint, pain (visual analog scale) patient compliance, and patient satisfaction.

RESULTS

There was no difference in the primary outcome between groups at 12 or 20 weeks; however, the Stack and dorsal splints had significant rates of treatment failure (23.8% in both groups, compared to none in the thermoplastic group; P=.04). There was a medium negative correlation between patient compliance and degree of extensor lag. No significant differences between groups were observed for patient satisfaction or pain.

CONCLUSIONS

As splints for mallet finger must be worn continuously for 6 to 8 weeks, and compliance correlates with favorable outcomes, treating practitioners must ensure the splint provided is robust enough for daily living requirements and does not cause complications, which are intolerable to the patient. In this study, no extensor lag difference was found between the 3 splint types, but custom-made thermoplastic splints were significantly less likely to result in treatment failure.

Для цитирования: O'Brien Lisa J, Bailey Michael J. Single blind, prospective, randomized controlled trial comparing dorsal aluminum and custom thermoplastic splints to stack splint for acute mallet finger.. Archives of physical medicine and rehabilitation. 2011. DOI: 10.1016/j.apmr.2010.10.035.