Postpartum Detection of Diastolic Dysfunction and Nondipping Blood Pressure Profile in Women With Preeclampsia.
Аннотация
BACKGROUND
Left ventricular diastolic dysfunction and nocturnal "nondipping" of blood pressure detected via ambulatory blood pressure monitoring are predictors of increased cardiovascular morbidity.
METHODS
A prospective cohort study including normotensive women with a history of preeclampsia in their current pregnancy was conducted. All cases were subjected to 24-hour ambulatory blood pressure monitoring and 2-dimensional transthoracic echocardiography 3 months after delivery.
RESULTS
This study included 128 women with a mean (SD) age of 28.6 (5.1) years and a mean (SD) basal blood pressure of 123.1 (6.4)/74.6 (5.9) mm Hg. Among the participants, 90 (70.3%) exhibited an ambulatory blood pressure monitoring profile illustrating nocturnal blood pressure "dipping" (the mean night to day time blood pressure ratio ≤ 0.9), whereas 38 (29.7%) were nondippers. Diastolic dysfunction (impaired left ventricular relaxation) was present in 28 nondippers (73.7%), whereas none of the dippers exhibited diastolic dysfunction. Women with severe preeclampsia were more frequently nondippers (35.5% vs 24.2%; P = .02) and experienced diastolic dysfunction (29% vs 15%; P = .01) than were those with mild preeclampsia. Severe preeclampsia (odds ratio [OR], 1.08; 95% CI, 1.05-10.56; P < .001) and history of recurrent preeclampsia (OR, 1.36; 95% CI, 1.3-4.26; P ≤ .001) were significant predictors for nondipping status and diastolic dysfunction (OR, 1.55; 95% CI, 1.1-2.2; and OR, 1.23; 95% CI, 1.2-2.2, respectively; P < .05).
CONCLUSION
Women with a history of preeclampsia were at higher risk for developing late cardiovascular events. The severity and recurrence of preeclampsia were significant predictors of both nondipping profile and diastolic dysfunction.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.