MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14767058.2016.1220532

Медицинская библиотека · The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians · 2016

To evaluate the prevalence of symptomatic and non-symptomatic ductus arteriosus and accuracy of physical signs in diagnosing PDA in preterm infants using blinded comparison of clinical and echocardiographic findings during the first week of life: a prospective observational study from Iran.

Pourarian Shahnaz, Sharma Deepak, Farahbakhsh Nazanin, Cheriki Sirous, Bijanzadeh Farhad

Сравнительное исследованиеСтатьяНаблюдательное исследованиеПеревод в очереди

Аннотация

AIMS: To evaluate the prevalence of symptomatic and non-symptomatic ductus arteriosus (PDA) and accuracy of physical signs in diagnosing PDA in preterm infants using blinded comparison of clinical and echocardiographic findings during the first week of life.

METHODS AND MATERIAL: This prospective observational cross-sectional study enrolled 200 preterm infants, who underwent echocardiography on 4th-7th postnatal day. The neonates who were diagnosed to have PDA on echo were observed for clinical features of PDA to label it symptomatic PDA. Symptomatic PDA was defined as detecting one or all of these symptoms in a neonate with PDA: bounding pulse, pericardial hyperactivity, systolic or continuous murmur.

RESULTS

Forty-five infants had PDA on echocardiography. 66.7% neonates with PDA were symptomatic and the most prevalent symptom in them was heart murmur (100%) either alone or combined with other clinical features. Isolated murmur was seen in 31.2%, murmur and hyperdynamic precordium was seen in 8.8%, murmur and bounding pulses were seen in 6.67% and all three features simultaneously were seen in 20% of infants. The sensitivity of murmur for diagnosing symptomatic PDA was highest.

CONCLUSION

Presence of murmur is the most important clinical feature for diagnosis of symptomatic PDA and has good specificity.

Для цитирования: Pourarian Shahnaz, Sharma Deepak, Farahbakhsh Nazanin, Cheriki Sirous, Bijanzadeh Farhad. To evaluate the prevalence of symptomatic and non-symptomatic ductus arteriosus and accuracy of physical signs in diagnosing PDA in preterm infants using blinded comparison of clinical and echocardiographic findings during the first week of life: a prospective observational study from Iran.. The journal of maternal-fetal & neonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians. 2016. DOI: 10.1080/14767058.2016.1220532.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.