PURPOSE: The purpose of the study is to evaluate the clinical safety and effectiveness of the Denali (Bard, Tempe, Arizona) retrievable inferior vena cava (IVC) filter.

MATERIALS AND

METHODS

In this retrospective study, authors reviewed the data of Denali IVC filters placed at their institution between 2013 and 2015. The clinical presentation, indications, and procedure-related complications during placement and retrieval were evaluated. The frequency of post filter pulmonary embolism (PE) and filter-related complications was assessed.

RESULTS

Denali filters were placed in 87 patients (47 males; mean age: 56 years). Twenty patients presented with PE, 45 with deep vein thrombosis (DVT), and 21 with both PE and DVT, 1 filter was placed prophylactically before surgery. Indications for filter placement included contraindications to anticoagulation (AC; n = 80), failure of AC (n = 4), and complications of AC (n = 3). No patients had PE on follow-up imaging after filter placement. Retrieval was attempted in 31 patients after a mean period of 125 days (range: 34-324 days). The filter was successfully removed in 31 (100%) patients. Follow-up imaging, available in 71 (82%) patients (range: 2-538 days), demonstrated penetration of 15 legs in 5 patients, caval thrombus in 3, 1 resulting in caval occlusion, <15° filter tilt in 5, and no leg fractures or crossed legs.

CONCLUSION

The Denali filter is safe during deployment and readily retrievable. The overall safety following deployment is similar to those reported in the literature, and the incidence of filter fractures and migration appears to be less than the previous generation of Bard devices.

Для цитирования: Reis Stephen P, Kovoor Jerry, Sutphin Patrick D, Toomay Seth, Trimmer Clayton, Pillai Anil, Reddick Mark, Kalva Sanjeeva P. Safety and Effectiveness of the Denali Inferior Vena Cava Filter: Intermediate Follow-Up Results.. Vascular and endovascular surgery. 2016. DOI: 10.1177/1538574416666223.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.