MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.identj.2022.10.007

Медицинская библиотека · International dental journal · 2022

Assessing Enamel Wear of Monolithic Ceramics With Micro-CT and Intra-oral Scanner.

Murbay Sukhdeep, Yeung Shadow Kim Wai, Yip Chui Ying, Pow Edmond Ho Nang

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

This in vitro study aimed to investigate enamel wear against 3 monolithic ceramics using 2 methods of measurement.

METHODS

Three groups of standard flat monolithic ceramic specimens including zirconia-reinforced lithium silicate glass (Vita Suprinity, VITA Zahnfabrik), yttria-stabilised tetragonal zirconia (Lava Esthetic Zirconia), and lithium disilicate glass (IPS e.max Press, Ivoclar Vivadent) were prepared, with human enamel used as the control group. Each specimen was subjected to the 2-body wear test at 49 N for 250,000 cycles. Enamel antagonists were evaluated with micro-computed tomography (CT) and intra-oral scanner, allowing 3-dimensional images of vertical wear and volumetric loss of enamel antagonists to be calculated. One-way analysis of variance followed by Student-Newman-Keuls post hoc tests were used to examine the differences in vertical wear/volumetric loss amongst the groups. Paired t tests and intra-class correlations were used to compare vertical wear/volumetric loss between the micro-CT and intra-oral scanner groups.

RESULTS

No significant difference in vertical wear was found amongst all groups. More volumetric loss was found in all test groups than in the control group (P < .001), but no significant difference was found amongst the test groups. There was a moderate positive correlation (r = 0.535, P = .033) between the vertical wear and volumetric loss. No significant difference between the 2 methods of measurement was found.

CONCLUSIONS

Monolithic ceramics induce more enamel wear than natural teeth. Both micro-CT and intra-oral scanners can be used for measuring tooth wear with similar performance.

Для цитирования: Murbay Sukhdeep, Yeung Shadow Kim Wai, Yip Chui Ying, Pow Edmond Ho Nang. Assessing Enamel Wear of Monolithic Ceramics With Micro-CT and Intra-oral Scanner.. International dental journal. 2022. DOI: 10.1016/j.identj.2022.10.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.