MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mat.0000000000001663

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2022

Safety and Efficacy of Prophylactic Amiodarone After Left Ventricular Assist Device.

Graboyes Sydney D T, Kline Theresa M, Harris Taylor N, Iyer Prashanth S, Hollis Ian B

СтатьяПеревод в очереди

Аннотация

The prophylactic use of amiodarone to reduce the incidence of postoperative arrhythmias is effective for patients undergoing general cardiac surgeries; however, no data exists for the use of prophylactic amiodarone to prevent postoperative arrhythmias after CF-LVAD. This single-center, retrospective analysis compared patients with CF-LVADs placed between April 2014 and June 2020 who received prophylactic postoperative amiodarone to those who did not. Based on institution practice at the respective times, patients with a CF-LVAD placed between April 2014 and June 2018 were included in the group receiving postoperative amiodarone arrhythmia prophylaxis and patients with a CF-LVAD placed July 2018 to June 2020 were included in the group not receiving arrhythmia prophylaxis. The primary outcome was the incidence of first occurring atrial or ventricular arrhythmia from CF-LVAD placement to 21 days or hospital discharge. Sixty patients received amiodarone for arrhythmia prophylaxis and 27 patients did not receive prophylaxis. The primary outcome occurred in 40% of the prophylaxis group and 66.7% in the no prophylaxis group (RR, 0.60; 95% CI, 0.40-0.90; p = 0.038). In patients receiving CF-LVADs, the use of prophylactic amiodarone was associated with a reduction in the incidence of postoperative arrhythmias, which was driven primarily by a reduction in postoperative atrial arrhythmias, without significantly increasing the rate of amiodarone-related adverse events.

Для цитирования: Graboyes Sydney D T, Kline Theresa M, Harris Taylor N, Iyer Prashanth S, Hollis Ian B. Safety and Efficacy of Prophylactic Amiodarone After Left Ventricular Assist Device.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2022. DOI: 10.1097/mat.0000000000001663.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.