MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.13182

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2017

Ivabradine in the treatment of postural tachycardia syndrome (POTS), a single center experience.

Ruzieh Mohammed, Sirianni Natalie, Ammari Zaid, Dasa Osama, Alhazmi Luai, Karabin Beverly, Grubb Blair

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Ivabradine is a selective If  channel blocker that reduces heart rate without affecting other cardiovascular functions. In case reports and case series, it was shown to improve symptoms in patients with postural tachycardia syndrome (POTS).

METHODOLOGY AND

RESULTS

This retrospective study examined patients who were diagnosed with POTS and received ivabradine as part of their treatment. Forty-nine patients (47 females, 95.9%) received ivabradine. The average age was 35.1 ± 10.35 years. The most common symptoms were palpitations and lightheadedness and both improved significantly, 88.4% and 76.1% response rate, respectively. A total of 38 patients reported improvement in their symptoms. In addition, ivabradine resulted in an objective decrease in sitting and standing heart rate (78.1 ± 10.7 vs 72.5 ± 7.6, P-value: 0.01) and (107.4 ± 14.1 vs 95.1 ± 13.7, P-value: < 0.001), respectively, with no significant change in blood pressure. The most common reported side effect was luminous phenomena/visual brightness occurring in nine patients. However, none of the patients stopped ivabradine due to side effects.

CONCLUSION

Our study shows that ivabradine is likely to be effective in treating patients with POTS. Nearly 78% of our cohort reported a significant improvement in symptoms with no major adverse effects reported. A future randomized, placebo-controlled trial is warranted.

Для цитирования: Ruzieh Mohammed, Sirianni Natalie, Ammari Zaid, Dasa Osama, Alhazmi Luai, Karabin Beverly, Grubb Blair. Ivabradine in the treatment of postural tachycardia syndrome (POTS), a single center experience.. Pacing and clinical electrophysiology : PACE. 2017. DOI: 10.1111/pace.13182.