BACKGROUND

Swept source optical coherence tomography angiography (SS-OCT-A) choroidal vasculography (CVG) is an imaging method which allows the evaluation of deep choroid details, being a promising too in choroidal pathologies as polypoidal choroidal vasculopathy (PCV).

RESEARCH DESIGN AND

METHODS

Cross-sectional study performed at FOSCAL International Clinic in Colombia. CVG features in patients with PCV were evaluated using SS-OCT CVG.

RESULTS

Twenty-two eyes of 21 patients were included. The mean age was 72.7 ± 6.5 years old (range: 48.6-95.4 years old). Twelve (57.1%) patients were male. The mean number of polyps detected by SS-OCT-A CVG before treatment with anti-VEGF therapy was 2.04 ± 1.18, which decreased after treatment to 1.18 ± 0.71. This result was statistically significant (p < 0.05). All polypoidal lesions detected by B-scan were visualized using CVG. Polyp circularity and surrounding reflectivity indicated activity of disease.

CONCLUSION

En face SS-OCT-A CVG is an alternative tool to evaluate choroidal structure at different depths without a contrast dye, providing information for the diagnosis and follow-up of patients with PCV. This imaging modality do not pretend to replace gold standard tests in PCV as ICGA, but rather provides choroidal imaging features of PCV, when ICGA is not available.

Для цитирования: Arias Juan D, Parra M Margarita, Hoyos Andrea T, Arango Francisco, Viteri Eduardo J, Arevalo J Fernando. En face swept-source optical coherence tomography angiography choroidal vasculography (CVG) a tool to discriminate choroidal abnormalities in polypoidal choroidal vasculopathy.. Expert review of medical devices. 2021. DOI: 10.1080/17434440.2021.1963230.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.