Cerebrospinal fluid leakage--reliable diagnostic methods.

Mantur Maria, Łukaszewicz-Zając Marta, Mroczko Barbara, Kułakowska Alina, Ganslandt Oliver, Kemona Halina, Szmitkowski Maciej, Drozdowski Wiesław, Zimmermann Rüdiger, Kornhuber Johannes, Lewczuk Piotr

СтатьяОбзорПеревод в очереди

Аннотация

Prompt diagnosis and early treatment of cerebrospinal fluid (CSF) leakage minimizes the risk of severe complications. In patients presenting with clear fluid nasal discharge it is important to identify the nature of the rhinorrhea. The CSF leakage may occur as post-traumatic, iatrogenic, spontaneous or idiopathic rhinorrhea. The differential diagnosis of CSF rhinorrhea often presents a challenging problem. The confirmation of CSF rhinorrhea and localization of the leakage may be diagnosed by CT, MRI cisternography and MRI cisternography in combination with single photon emission tomography or radioisotopic imaging. Although these methods allow estimation of the CSF leakage with high accuracy, they are expensive and invasive procedures. Therefore, biochemical methods are still used in the differentiation. Although the most common diagnostic method for screening CSF leakage is glucose oxidase, its diagnostic sensitivity and specificity is generally unsatisfactory. False negative results may occur with bacterial contamination and false positive results are common in diabetic patients. Glucose detection is not recommended as a confirmatory test. As such, other biomarkers of the CSF leakage, such as beta-2-transferrin (beta-2 trf) and beta-trace protein (betaTP) are necessary to identify and confirm of this condition.

Для цитирования: Mantur Maria, Łukaszewicz-Zając Marta, Mroczko Barbara, Kułakowska Alina, Ganslandt Oliver, Kemona Halina, Szmitkowski Maciej, Drozdowski Wiesław, Zimmermann Rüdiger, Kornhuber Johannes, Lewczuk Piotr. Cerebrospinal fluid leakage--reliable diagnostic methods.. Clinica chimica acta; international journal of clinical chemistry. 2011. DOI: 10.1016/j.cca.2011.02.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.