MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinimag.2012.09.016

Медицинская библиотека · Clinical imaging · 2012

Renal cyst pseudoenhancement at 16- and 64-dector row MDCT.

Sai Victor, Rakow-Penner Rebecca, Yeh Benjamin M, Coakley Fergus V, Westphalen Antonio C, Webb Emma M, Wang Zhen J

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

To evaluate the presence of renal cyst pseudoenhancement at 16- and 64-row multidetector computed tomography (MDCT) in patients.

METHODS

MDCT images from 90 patients with renal cysts >1 cm in diameter (n=122) were retrospectively analyzed for the presence and predictors of cyst pseudoenhancement.

RESULTS

Fifty-three percent of cysts 1-2 cm demonstrated pseudoenhancement (ranged from 11 to 35 HU). Cyst pseudoenhancement was more pronounced when imaged with 64-row CTs compared to 16-row CT. Cyst size, postcontrast renal parenchymal density, and number of scanner detector rows were independent predictors of pseudoenhancement.

CONCLUSION

Pseudoenhancement occurs most frequently in patients with renal cysts <2 cm imaged with 64-detector-row MDCT.

Для цитирования: Sai Victor, Rakow-Penner Rebecca, Yeh Benjamin M, Coakley Fergus V, Westphalen Antonio C, Webb Emma M, Wang Zhen J. Renal cyst pseudoenhancement at 16- and 64-dector row MDCT.. Clinical imaging. 2012. DOI: 10.1016/j.clinimag.2012.09.016.