MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/la201360p

Медицинская библиотека · Langmuir : the ACS journal of surfaces and colloids · 2011

Thermoresponsive polymer brush on monolithic-silica-rod for the high-speed separation of bioactive compounds.

Nagase Kenichi, Kobayashi Jun, Kikuchi Akihiko, Akiyama Yoshikatsu, Kanazawa Hideko, Okano Teruo

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Poly(N-isopropylacrylamide), one of the most utilized thermoresponsive polymers, brush-grafted monolithic-silica columns were prepared through surface-initiated atom transfer radical polymerization (ATRP) for effective thermoresponsive-chromatography matrices. ATRP initiator was grafted on monolithic silica-rod surfaces by flowing a toluene solution containing ATRP initiator into monolithic silica-rod columns. N-Isopropylacrylamide (IPAAm) monomer and CuCl/CuCl(2)/Me(6)TREN, an ATRP catalytic system, were dissolved in 2-propanol, and the reaction solution was pumped into the preprepared initiator-modified columns at 25 °C for 16 h. The constructed PIPAAm-brush structure on the monolithic silica-rod surface was confirmed by XPS, elemental analysis, SEM observation, and GPC measurement of grafted PIPAAm. The prepared monolithic silica-rod columns were also characterized by chromatographic analysis. PIPAAm-brush-modified monolithic silica-rod columns were able to separate hydrophobic steroids with a short analysis time (10 min), compared to PIPAAm-brush-modified silica-beads-packed columns, because of the horizontally limited diffusion path length of monolithic supporting materials. Additionally, diluted PIPAAm-brush monolithic silica-rod column gave a further shorting analysis time (5 min). These results indicated (1) surface-initiated ATRP constructed PIPAAm-brush structures on monolithic silica-rod surfaces and (2) PIPAAm-brush grafted monolithic silica-rod column prepared by ATRP was a promising tool for analyzing hydrophobic-bioactive compounds with a short analysis time.

Для цитирования: Nagase Kenichi, Kobayashi Jun, Kikuchi Akihiko, Akiyama Yoshikatsu, Kanazawa Hideko, Okano Teruo. Thermoresponsive polymer brush on monolithic-silica-rod for the high-speed separation of bioactive compounds.. Langmuir : the ACS journal of surfaces and colloids. 2011. DOI: 10.1021/la201360p.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.