MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2016.11.011

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2016

Inferior Vena Cava Compression as a Novel Maneuver to Detect Patent Foramen Ovale: A Transesophageal Echocardiographic Study.

Yamashita Eiji, Murata Tomoyuki, Goto Eri, Fujiwara Takeshi, Sasaki Takehito, Minami Kentaro, Nakamura Kohki, Kumagai Koji, Naito Shigeto, Kario Kazuomi, Oshima Shigeru

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The Valsalva maneuver, the most sensitive test for patent foramen ovale (PFO) detection, is difficult during transesophageal echocardiography (TEE), especially after sedation. The aim of this study was to compare PFO detection effectiveness between inferior vena cava (IVC) compression and the Valsalva maneuver.

METHODS

A total of 293 patients with paroxysmal atrial fibrillation undergoing TEE before initial atrial fibrillation ablation were prospectively enrolled. Agitated saline was injected in 290 patients under three conditions: Valsalva maneuver under conscious sedation, at rest, and IVC compression under deep sedation. Three patients with newly diagnosed atrial septal defects on TEE were excluded. The IVC compression maneuver consisted of manual compression 5 cm to the right of the epigastric region and depressed the abdominal wall by 5 cm for 30 sec and compression release immediately before right atrial opacification with microbubbles by agitated intravenous saline.

RESULTS

The overall PFO detection rate was better with IVC compression (57 PFOs [19.7%]) than at rest (15 patients [5.2%]) (P < .0001) or with the Valsalva maneuver (37 patients [12.8%]) (P = .024). There were no significant differences in PFO detection between IVC compression and the Valsalva maneuver (IVC compression, 43 patients [22.5%]; Valsalva maneuver, 35 patients [18.3%]; P = .31), even in patients who could perform the Valsalva maneuver effectively (n = 191).

CONCLUSIONS

IVC compression is feasible and effective for detecting PFO and is not inferior to the Valsalva maneuver. In particular, IVC compression could be an alternative diagnostic method for PFO using TEE when the Valsalva maneuver cannot be performed under deep sedation.

Для цитирования: Yamashita Eiji, Murata Tomoyuki, Goto Eri, Fujiwara Takeshi, Sasaki Takehito, Minami Kentaro, Nakamura Kohki, Kumagai Koji, Naito Shigeto, Kario Kazuomi, Oshima Shigeru. Inferior Vena Cava Compression as a Novel Maneuver to Detect Patent Foramen Ovale: A Transesophageal Echocardiographic Study.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2016. DOI: 10.1016/j.echo.2016.11.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.