DOI 10.1007/s12149-007-0092-1

Медицинская библиотека · Annals of nuclear medicine · 2008

Improved detection of breast cancer on FDG-PET cancer screening using breast positioning device.

Kaida Hayato, Ishibashi Masatoshi, Fujii Teruhiko, Kurata Seiji, Ogo Etsuyo, Tanaka Maki, Hayabuchi Naofumi

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim of this study was to investigate the detection rate of breast cancer by positron emission tomography cancer screening using a breast positioning device.

METHODS

Between January 2004 and January 2006, 1,498 healthy asymptomatic individuals underwent cancer screening by fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) at our institution; 660 of 1498 asymptomatic healthy women underwent breast PET imaging in the prone position using the breast positioning device to examine the mammary glands in addition to whole-body PET imaging. All subjects that showed abnormal (18)F-FDG uptake in the mammary glands were referred for further examination or surgery at our institution or a local hospital. Our data were compared with the histopathological findings or findings of other imaging modalities in our institution and replies from the doctors at another hospital.

RESULTS

Of the 660 participants, 7 (1.06%) were found to have breast cancers at a curable stage. All the seven cancers were detected by breast PET imaging, but only five of these were detected by whole-body PET imaging; the other two were detected by breast PET imaging using the breast positioning device.

CONCLUSIONS

In cancer screening, prone breast imaging using a positioning device may help to improve the detection rate of breast cancer. However, overall cancer including mammography and ultrasonography screening should be performed to investigate the false-negative cases and reduce false-positive cases. The effectiveness of prone breast PET imaging in cancer screening should be investigated using a much larger number of cases in the near future.

Для цитирования: Kaida Hayato, Ishibashi Masatoshi, Fujii Teruhiko, Kurata Seiji, Ogo Etsuyo, Tanaka Maki, Hayabuchi Naofumi. Improved detection of breast cancer on FDG-PET cancer screening using breast positioning device.. Annals of nuclear medicine. 2008. DOI: 10.1007/s12149-007-0092-1.