Медицинская библиотека · Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2021

Mechanics of Total Drum Replacement Tympanoplasty Studied With Wideband Acoustic Immittance.

Eberhard Kristine Elisabeth, Masud Salwa Fatima, Knudson Inge M, Kirubalingam Keshinisuthan, Khalid Hamza, Remenschneider Aaron K, Nakajima Hideko Heidi

СтатьяПоддержка исследования: вне правительства СШАПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

OBJECTIVE

Poor hearing outcomes often persist following total drum replacement tympanoplasty. To understand the mechanics of the reconstructed eardrum, we measured wideband acoustic immittance and compared the mechanical characteristics of fascia-grafted ears with the normal tympanic membrane.

STUDY

DESIGN

Prospective comparison study.

SETTING

Tertiary care center.

METHODS

Patients who underwent uncomplicated total drum replacement with temporalis fascia grafts were identified. Ears with healed grafts, an aerated middle ear, and no other conductive abnormalities were included. All patients underwent pre- and postoperative audiometry. Wideband acoustic immittance was measured with absorbance and impedance computed. Fascia-grafted ears were compared with normal unoperated ears.

RESULTS

Eleven fascia-grafted ears without complications were included. Postoperatively, the median air-bone gap was 15 dB (250-4000 Hz), with variation across frequency and between ears. Fifty-six control ears were included. Absorbance of fascia-grafted ears was significantly lower than that of normal ears at 1 to 4 kHz (P < .05) but similar below 1 kHz. Impedance magnitude demonstrated deeper and sharper resonant notches in fascia-grafted ears than normal ears (P < .05), suggesting lower mechanical resistance of the fascia graft.

CONCLUSION

The mechanics of fascia-grafted ears differ from the normal tympanic membrane by having lower absorbance at mid- to high frequencies and thus poor sound transmission. The lower resistance in fascia-grafted ears may be due to poor coupling of the graft to the malleus. To improve sound transmission, grafts for tympanic membrane reconstructions would benefit from refined mechanical properties.

Для цитирования: Eberhard Kristine Elisabeth, Masud Salwa Fatima, Knudson Inge M, Kirubalingam Keshinisuthan, Khalid Hamza, Remenschneider Aaron K, Nakajima Hideko Heidi. Mechanics of Total Drum Replacement Tympanoplasty Studied With Wideband Acoustic Immittance.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2021. DOI: 10.1177/01945998211029541.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.