Echocardiographic Assessment of Cardiac Function by Conventional and Speckle-Tracking Echocardiography in Dogs with Patent Ductus Arteriosus.

Spalla I, Locatelli C, Zanaboni A M, Brambilla P, Bussadori C

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Patent ductus arteriosus (PDA) is one of the most common congenital heart defects in dogs. Advanced echocardiographic techniques such as speckle-tracking echocardiography (STE) have not been extensively used to evaluate cardiac function in affected dogs.

HYPOTHESIS: Advanced echocardiographic techniques are more sensitive than standard echocardiographic techniques in analyzing systolic function in dogs with PDA.

ANIMALS: Forty-four client-owned dogs: 34 dogs with PDA (preoperative evaluation) and 10 healthy sex- and weight-matched controls.

METHODS

Prospective study. Dogs were recruited over a 2-year period. Complete echocardiographic evaluation was performed, including conventional (end-diastolic volumes indexed to body surface area in B and M-mode [EDVIB /M ], end-systolic volumes indexed to body surface area in B and M-mode [ESVIB /M ], allometric scaling in diastole and systole [AlloD/S], pulmonary flow to systemic flow [Qp/Qs], ejection fraction [EF] and fractional shortening [FS]) and speckle-tracking echocardiography ([STE]: global longitudinal, radial and circumferential strain [S] and strain rate [SR]).

RESULTS

Dogs with PDA had significantly different EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs and all STE-derived parameters (global longitudinal S and SR, global circumferential S and SR, global radial S and SR)compared to healthy dogs. No correlation was found between standard techniques (EDVIB /M , ESVIB /M , AlloD/S, Qp/Qs) and STE-derived parameters (global longitudinal, circumferential and radial S and SR).

CONCLUSION AND CLINICAL

IMPORTANCE

Conventional parameters routinely used to assess systolic function (EF and FS) were not different between the groups; STE-derived parameters identified subtle changes in cardiac systolic function and contractility between the 2 groups of dogs. Based on these findings, STE may be a more appropriate tool to assess cardiac contractility in dogs with PDA.

Для цитирования: Spalla I, Locatelli C, Zanaboni A M, Brambilla P, Bussadori C. Echocardiographic Assessment of Cardiac Function by Conventional and Speckle-Tracking Echocardiography in Dogs with Patent Ductus Arteriosus.. Journal of veterinary internal medicine. 2016. DOI: 10.1111/jvim.13938.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.