DOI 10.1016/j.ijcard.2018.07.139

Медицинская библиотека · International journal of cardiology · 2018

Subcutaneous implantable cardioverter defibrillator implantation: An analysis of Italian clinical practice and its evolution.

D'Onofrio Antonio, Pieragnoli Paolo, Biffi Mauro, Nigro Gerardo, Migliore Federico, Francia Pietro, De Filippo Paolo, Capucci Alessandro, Botto Giovanni Luca, Giammaria Massimo, Palmisano Pietro, Pisanò Ennio, Bisignani Giovanni, La Greca Carmelo, Sarubbi Berardo, Sala Simone, Viscusi Miguel, Landolina Maurizio, Lovecchio Mariolina, Valsecchi Sergio, Bongiorni Maria Grazia, "S-ICD Rhythm Detect" Investigators

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

BACKGROUND

The subcutaneous implantable cardioverter defibrillator (S-ICD) is a relatively novel alternative to the transvenous ICD for the treatment of life-threatening ventricular arrhythmias, and is currently used in the clinical practice of several centers. The aim of this analysis was to describe current Italian practice regarding S-ICD implantation and its evolution over the years.

METHODS

We analyzed 607 consecutive patients (78% male, 48 ± 16 years) who underwent S-ICD implantation in 39 Italian centers from 2013 to 2017.

RESULTS

Structural cardiomyopathy was present in 78% of patients and 30% of patients received their device for secondary prevention. The proportion of patients with dilated cardiomyopathy and with left ventricular ejection fraction ≤35% increased from ≤2014 to 2017 (from 38% to 58%, from 33% to 53%, respectively; both p < 0.05). Almost all procedures (97%) were performed in electrophysiology laboratories. Over the last 4 years, the 2-incision implantation technique has been widely adopted, with sub- or inter-muscular positioning of the generator, under local anesthesia or deep sedation (≤2014 versus 2017: all p < 0.001). Defibrillation testing was performed in 81% of patients. Shock energy of ≤65 J was successful in 93.9% of patients and the overall cardioversion success rate at ≤80 J was 99.8%.

CONCLUSIONS

Our analysis confirmed that the S-ICD continues to be preferentially used in specific patients (younger, less frequently with dilated cardiomyopathy and low ejection fraction.). Nonetheless, we noted a trend toward the wider use of S-ICD in patients with dilated cardiomyopathy and systolic dysfunction over the years. Novel approaches have been adopted while the acute efficacy of the system has remained stably high.

Для цитирования: D'Onofrio Antonio, Pieragnoli Paolo, Biffi Mauro, Nigro Gerardo, Migliore Federico, Francia Pietro, De Filippo Paolo, Capucci Alessandro, Botto Giovanni Luca, Giammaria Massimo, Palmisano Pietro, Pisanò Ennio, Bisignani Giovanni, La Greca Carmelo, Sarubbi Berardo, Sala Simone, Viscusi Miguel, Landolina Maurizio, Lovecchio Mariolina, Valsecchi Sergio, Bongiorni Maria Grazia, "S-ICD Rhythm Detect" Investigators. Subcutaneous implantable cardioverter defibrillator implantation: An analysis of Italian clinical practice and its evolution.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.07.139.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.