m+Medelevator.RU
← Поиск публикаций
Journal of clinical anesthesia · 2023

Neuromuscular end-point predictive capability of published rocuronium pharmacokinetic/pharmacodynamic models: An observational trial.

Наблюдательное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Carvalho Hugo, Verdonck Michaël, Eleveld Douglas J, Ramirez David, D'Haese Jan, Flamée Panagiotis, Geerts Lieselot, Wylleman Jasper, Cools Wilfried, Barbe Kurt, Struys Michel M R F, Poelaert Jan

Аннотация

BACKGROUND: Objective neuromuscular monitoring remains the single most reliable method to ensure optimal perioperative neuromuscular management. Nevertheless, the prediction of clinical neuromuscular endpoints by means of Pharmacokinetic (PK) and Pharmacodynamic (PD) modelling has the potential to complement monitoring and improve perioperative neuromuscular management.s STUDY OBJECTIVE: The present study aims to assess the performance of published Rocuronium PK/PD models in predicting intraoperative Train-of-four (TOF) ratios when benchmarked against electromyographic TOF measurements.

DESIGN: Observational trial.

SETTING: Tertiary Belgian hospital, from August 2020 up to September 2021.

PATIENTS AND INTERVENTIONS: Seventy-four patients undergoing general anaesthesia for elective surgery requiring the administration of rocuronium and subject to continuous EMG neuromuscular monitoring were included. PK/PD-simulated TOF ratios were plotted and synchronised with their measured electromyographic counterparts and their differences analysed by means of Predictive Error derivatives (Varvel criteria).

MAIN RESULTS: Published rocuronium PK/PD models overestimated clinically registered TOF ratios. The models of Wierda, Szenohradszky, Cooper, Alvarez-Gomez and McCoy showed significant predictive consistency between themselves, displaying Median Absolute Performance Errors between 38% and 41%, and intra-individual differences (Wobble) between 14 and 15%. The Kleijn model outperformed the former with a lower Median Absolute Performance Error (16%, 95%CI [0.01; 57]) and Wobble (11%, 95%CI [0.01; 34]). All models displayed considerably wide 95% confidence intervals for all performance metrics, suggesting a significantly variable performance.

CONCLUSIONS: Simulated TOF ratios based on published PK/PD models do not accurately predict real intraoperative TOF ratio dynamics.

TRIAL REGISTRATION: NCT04518761 (clinicaltrials.gov), registered on 19 August 2020.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты