Медицинская библиотека · Cardiovascular revascularization medicine : including molecular interventions · 2021

Saline as an Alternative to Radio-Contrast for Optical Coherence Tomography-Guided Percutaneous Coronary Intervention: A Prospective Comparison.

Gupta Ankush, Chhikara Sanya, Vijayvergiya Rajesh, Seth Ashok, Mahesh Nalin K, Akasaka Takashi, Singh Navreet

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To do a quantitative comparison of saline and contrast Frequency domain optical coherence tomography (FD-OCT) during percutaneous coronary intervention (PCI) optimisation.

METHODS

13 pairs of OCT runs were analysed, wherein each pair consisted of a contrast run and a heparinized saline run taken in the same coronary artery at the same position. Quantitative analysis was done comparing minimal lumen area (MLA), proximal reference diameter (PRD), distal reference diameter (DRD) and percentage area stenosis (AS) at the same anatomical location. Lesion morphologies, rendered stent view and 3D reconstruction were compared for image clarity.

RESULT: The saline OCT runs resulted in comparable MLA (3.88 ± 2.59 mm2 with saline run vs 3.88 ± 2.71 mm2 with contrast run; p = 0.650), PRD (3.66 ± 0.52 mm with saline vs 3.65 ± 0.52 mm with contrast; p = 0.463), DRD (2.97 ± 0.22 mm with saline vs 2.99 ± 0.88 mm with contrast; p = 0.433), and AS (59.60 ± 18.62% with saline vs 59.18 ± 19.11% with contrast; p = 0.753) with respect to the contrast runs. The Bland Altman plots of the measured parameters indicate good agreement between saline and contrast OCT. Linear regression analysis indicated the absence of proportional bias All lesion morphologies (calcified, fibrotic, thin cap fibroatheroma, macrophages, cholesterol crystals and edge dissection), 3D reconstruction and rendered stent view were clearly demonstrable in the saline OCT runs.

CONCLUSIONS

Using heparinized saline as flushing media in coronary FD-OCT may result in vessel dimensions that are comparable with contrast. Heparinized saline may be used as a contrast saving alternative for FD-OCT during PCI optimization.

Для цитирования: Gupta Ankush, Chhikara Sanya, Vijayvergiya Rajesh, Seth Ashok, Mahesh Nalin K, Akasaka Takashi, Singh Navreet. Saline as an Alternative to Radio-Contrast for Optical Coherence Tomography-Guided Percutaneous Coronary Intervention: A Prospective Comparison.. Cardiovascular revascularization medicine : including molecular interventions. 2021. DOI: 10.1016/j.carrev.2021.01.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.