MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0974-2069.180672

Медицинская библиотека · Annals of pediatric cardiology · 2016

Successful retrieval of a Figulla Occlutech septal occluder - embolized device stability and potential solutions.

Sadiq Masood, Ur Rehman Asif, Mehmood Amjad

Клинический случайСтатьяПеревод в очереди

Аннотация

Go to: We report a case of an atrial septal defect where a Figulla Occlutech device embolized into the right ventricle. As this device has no left atrial hub, we brought the bare device into the inferior vena cava and used a novel two-snare technique to slenderize the device into the sheath. This report highlights additional tips in transcatheter device retrieval.

Для цитирования: Sadiq Masood, Ur Rehman Asif, Mehmood Amjad. Successful retrieval of a Figulla Occlutech septal occluder - embolized device stability and potential solutions.. Annals of pediatric cardiology. 2016. DOI: 10.4103/0974-2069.180672.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.