MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jvir.2016.08.009

Медицинская библиотека · Journal of vascular and interventional radiology : JVIR · 2016

Randomized Controlled Trial of Octyl Cyanoacrylate Skin Adhesive versus Subcuticular Suture for Skin Closure after Implantable Venous Port Placement.

Martin Jonathan G, Hollenbeck Scott T, Janas Gemini, Makar Ryan A, Pabon-Ramos Waleska M, Suhocki Paul V, Miller Michael J, Sopko David R, Smith Tony P, Kim Charles Y

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To compare early outcomes of skin closure with octyl cyanoacrylate skin adhesive versus subcuticular suture closure.

MATERIALS AND

METHODS

Over a 7-month period, 109 subjects (28 men and 81 women; mean age, 58.6 y) scheduled to undergo single-lumen implantable venous port insertion for chemotherapy were randomly assigned to skin closure with either octyl cyanoacrylate skin adhesive or absorbable subcuticular suture after suturing the deep dermal layer. Subjects were followed for episodes of infection or dehiscence within 3 months of port implantation. At 3 months, photographs of the healed incision were obtained and reviewed by a plastic surgeon in a blinded fashion who rated cosmetic scar appearance based on a validated 10-point cosmesis score.

RESULTS

Of subjects, 54 were randomly assigned to skin adhesive, and 55 were randomly assigned to subcuticular suture. No subjects had incision dehiscence. Infection rates at 3 months were similar between groups (2.1% vs 4.0%; P = 1.0). The mean cosmesis scores were 4.40 for skin adhesive and 4.46 for subcuticular suture (P = .898). The superficial skin closure time was 8.6 minutes for suture versus 1.4 minutes for skin adhesive (P < .001).

CONCLUSIONS

Scar cosmesis and patient outcomes did not significantly vary between skin adhesive versus subcuticular suture, although skin closure time was significantly less with skin adhesive.

Для цитирования: Martin Jonathan G, Hollenbeck Scott T, Janas Gemini, Makar Ryan A, Pabon-Ramos Waleska M, Suhocki Paul V, Miller Michael J, Sopko David R, Smith Tony P, Kim Charles Y. Randomized Controlled Trial of Octyl Cyanoacrylate Skin Adhesive versus Subcuticular Suture for Skin Closure after Implantable Venous Port Placement.. Journal of vascular and interventional radiology : JVIR. 2016. DOI: 10.1016/j.jvir.2016.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.