MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1161/circimaging.113.001541

Медицинская библиотека · Circulation. Cardiovascular imaging · 2014

Determination of location, size, and transmurality of chronic myocardial infarction without exogenous contrast media by using cardiac magnetic resonance imaging at 3 T.

Kali Avinash, Cokic Ivan, Tang Richard L Q, Yang Hsin-Jung, Sharif Behzad, Marbán Eduardo, Li Debiao, Berman Daniel S, Dharmakumar Rohan

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Late-gadolinium-enhanced (LGE) cardiac MRI (CMR) is a powerful method for characterizing myocardial infarction (MI), but the requisite gadolinium infusion is estimated to be contraindicated in ≈20% of patients with MI because of end-stage chronic kidney disease. The purpose of this study is to investigate whether T1 CMR obtained without contrast agents at 3 T could be an alternative to LGE CMR for characterizing chronic MIs using a canine model of MI.

METHODS AND

RESULTS

Canines (n=29) underwent CMR at 7 days (acute MI [AMI]) and 4 months (chronic MI [CMI]) after MI. Infarct location, size, and transmurality measured by using native T1 maps and LGE images at 1.5 T and 3 T were compared. Resolution of edema between AMI and CMI was examined with T2 maps. T1 maps overestimated infarct size and transmurality relative to LGE images in AMI (P=0.016 and P=0.007, respectively), which was not observed in CMI (P=0.49 and P=0.81, respectively) at 3 T. T1 maps underestimated infarct size and transmurality relative to LGE images in AMI and CMI (P<0.001) at 1.5 T. Relative to the remote territories, T1 of the infarcted myocardium was increased in CMI and AMI (P<0.05), and T2 of the infarcted myocardium was increased in AMI (P<0.001) but not in CMI (P>0.20) at both field strengths. Histology showed extensive replacement fibrosis within the CMI territories. CMI detection sensitivity and specificity of T1 CMR at 3 T were 95% and 97%, respectively.

CONCLUSIONS

Native T1 maps at 3 T can determine the location, size, and transmurality of CMI with high diagnostic accuracy. Patient studies are necessary for clinical translation.

Для цитирования: Kali Avinash, Cokic Ivan, Tang Richard L Q, Yang Hsin-Jung, Sharif Behzad, Marbán Eduardo, Li Debiao, Berman Daniel S, Dharmakumar Rohan. Determination of location, size, and transmurality of chronic myocardial infarction without exogenous contrast media by using cardiac magnetic resonance imaging at 3 T.. Circulation. Cardiovascular imaging. 2014. DOI: 10.1161/circimaging.113.001541.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.