A step-wise approach for analysis of the mouse embryonic heart using 17.6Tesla MRI.

Gabbay-Benziv Rinat, Reece E Albert, Wang Fang, Bar-Shir Amnon, Harman Chris, Turan Ozhan M, Yang Peixin, Turan Sifa

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The mouse embryo is ideal for studying human cardiac development. However, laboratory discoveries do not easily translate into clinical findings partially because of histological diagnostic techniques that induce artifacts and lack standardization.

AIM: To present a step-wise approach using 17.6T MRI, for evaluation of mice embryonic heart and accurate identification of congenital heart defects.

SUBJECTS: 17.5-embryonic days embryos from low-risk (non-diabetic) and high-risk (diabetic) model dams.

STUDY

DESIGN

Embryos were imaged using 17.6Tesla MRI. Three-dimensional volumes were analyzed using ImageJ software.

OUTCOME MEASURES: Embryonic hearts were evaluated utilizing anatomic landmarks to locate the four-chamber view, the left- and right-outflow tracts, and the arrangement of the great arteries. Inter- and intra-observer agreement were calculated using kappa scores by comparing two researchers' evaluations independently analyzing all hearts, blinded to the model, on three different, timed occasions. Each evaluated 16 imaging volumes of 16 embryos: 4 embryos from normal dams, and 12 embryos from diabetic dams.

RESULTS

Inter-observer agreement and reproducibility were 0.779 (95% CI 0.653-0.905) and 0.763 (95% CI 0.605-0.921), respectively. Embryonic hearts were structurally normal in 4/4 and 7/12 embryos from normal and diabetic dams, respectively. Five embryos from diabetic dams had defects: ventricular septal defects (n=2), transposition of great arteries (n=2) and Tetralogy of Fallot (n=1). Both researchers identified all cardiac lesions.

CONCLUSION

A step-wise approach for analysis of MRI-derived 3D imaging provides reproducible detailed cardiac evaluation of normal and abnormal mice embryonic hearts. This approach can accurately reveal cardiac structure and, thus, increases the yield of animal model in congenital heart defect research.

Для цитирования: Gabbay-Benziv Rinat, Reece E Albert, Wang Fang, Bar-Shir Amnon, Harman Chris, Turan Ozhan M, Yang Peixin, Turan Sifa. A step-wise approach for analysis of the mouse embryonic heart using 17.6Tesla MRI.. Magnetic resonance imaging. 2016. DOI: 10.1016/j.mri.2016.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.