MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1055/s-0036-1581081

Медицинская библиотека · American journal of perinatology · 2016

Quantitative, Noninvasive Assessment of Patent Ductus Arteriosus Shunt Flow by Measuring Proximal Isovelocity Surface Area on Color Doppler Mapping in Very Low-Birth-Weight Infants.

Iwashima Satoru, Ishikawa Takamichi

СтатьяПеревод в очереди

Аннотация

Background Our goal was to evaluate the hemodynamic status of very low-birth-weight infants (VLBWIs) with patent ductus arteriosus (PDA) by measuring the vena contracta width (VCW) and effective shunt orifice area (ESOA) using the proximal isovelocity surface area (PISA) on color Doppler imaging. Method and Results In this study, 34 VLBWIs with PDA (median weight: 949 g) were studied. We measured VCW and ESOA using the PISA on echocardiography. PDA-VCW was measured at the narrowest PDA flow region. ESOA determined using PISA (PDA-ESOA) was defined as the hemispheric area of laminar flow with aliased velocities on color Doppler flow imaging: PDA-ESOA = 2π (PDA radius) 2 × aligning velocity/PDA velocity. Of the 34 VLBWIs, 26 received indomethacin (IND) for symptomatic PDA. Comparing echocardiographic parameters between infants who did versus did not receive IND, significant differences were seen in the left atrial-to-aortic root ratio (LA/AO), PDA-VCW, and PDA-ESOA. Receiver operating characteristic curve analysis to differentiate between IND usage status produced statistically significant results for PDA-VCW (area under the curve [AUC] = 0.880), PDA-ESOA (AUC = 0.813), and LA/AO (AUC = 0.769). Conclusion PDA-VCW and PDA-ESOA may allow noninvasive assessment of PDA severity, and are useful when determining the timing of clinical decision making for IND administration.

Для цитирования: Iwashima Satoru, Ishikawa Takamichi. Quantitative, Noninvasive Assessment of Patent Ductus Arteriosus Shunt Flow by Measuring Proximal Isovelocity Surface Area on Color Doppler Mapping in Very Low-Birth-Weight Infants.. American journal of perinatology. 2016. DOI: 10.1055/s-0036-1581081.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.