Standing Balance Conditions and Digital Sway Measures for Clinical Trials of Friedreich's Ataxia.

Casey Hannah L, Shah Vrutangkumar V, Muzyka Daniel, McNames James, El-Gohary Mahmoud, Sowalsky Kristen, Safarpour Delaram, Carlson-Kuhta Patricia, Schmahmann Jeremy D, Rosenthal Liana S, Perlman Susan, Rummey Christian, Horak Fay B, Gomez Christopher M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Progressive loss of standing balance is a feature of Friedreich's ataxia (FRDA).

OBJECTIVES

This study aimed to identify standing balance conditions and digital postural sway measures that best discriminate between FRDA and healthy controls (HC). We assessed test-retest reliability and correlations between sway measures and clinical scores.

METHODS

Twenty-eight subjects with FRDA and 20 HC completed six standing conditions: feet apart, feet together, and feet tandem, both with eyes opened (EO) and eyes closed. Sway was measured using a wearable sensor on the lumbar spine for 30 seconds. Test completion rate, test-retest reliability with intraclass correlation coefficients, and areas under the receiver operating characteristic curves (AUCs) for each measure were compared to identify distinguishable FRDA sway characteristics from HC. Pearson correlations were used to evaluate the relationships between discriminative measures and clinical scores.

RESULTS

Three of the six standing conditions had completion rates over 70%. Of these three conditions, natural stance and feet together with EO showed the greatest completion rates. All six of the sway measures' mean values were significantly different between FRDA and HC. Four of these six measures discriminated between groups with >0.9 AUC in all three conditions. The Friedreich Ataxia Rating Scale Upright Stability and Total scores correlated with sway measures with P-values <0.05 and r-values (0.63-0.86) and (0.65-0.81), respectively.

CONCLUSION

Digital postural sway measures using wearable sensors are discriminative and reliable for assessing standing balance in individuals with FRDA. Natural stance and feet together stance with EO conditions suggest use in clinical trials for FRDA. © 2024 International Parkinson and Movement Disorder Society.

Для цитирования: Casey Hannah L, Shah Vrutangkumar V, Muzyka Daniel, McNames James, El-Gohary Mahmoud, Sowalsky Kristen, Safarpour Delaram, Carlson-Kuhta Patricia, Schmahmann Jeremy D, Rosenthal Liana S, Perlman Susan, Rummey Christian, Horak Fay B, Gomez Christopher M. Standing Balance Conditions and Digital Sway Measures for Clinical Trials of Friedreich's Ataxia.. Movement disorders : official journal of the Movement Disorder Society. 2024. DOI: 10.1002/mds.29777.