MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jacep.2022.07.010

Медицинская библиотека · JACC. Clinical electrophysiology · 2022

Safety of Pill-in-the-Pocket Class 1C Antiarrhythmic Drugs for Atrial Fibrillation.

Markman Timothy M, Jarrah Andrew A, Tian Ye, Mustin Evan, Guandalini Gustavo S, Lin David, Epstein Andrew E, Hyman Matthew C, Deo Rajat, Supple Gregory E, Arkles Jeffrey S, Dixit Sanjay, Schaller Robert D, Santangeli Pasquale, Nazarian Saman, Riley Michael, Callans David J, Marchlinski Francis E, Frankel David S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Guidelines recommend that initial trial of a "pill-in-the-pocket" (PIP) Class 1C antiarrhythmic drug (AAD) for cardioversion of atrial fibrillation (AF) be performed in a monitored setting because of the potential for adverse reactions.

OBJECTIVES

This study sought to characterize real-world, contemporary use of the PIP approach, including the setting of initiation and incidence of adverse events.

METHODS

This retrospective cohort study included all patients at the Hospital of the University of Pennsylvania treated with a PIP approach for AF between 2007 and 2020.

RESULTS

A total of 273 patients (age 56 ± 13 years; 182 [67%] male; CHA2DS2VASc score 1.1 ± 1.2) took a first dose of PIP AAD. Flecainide was used in 151 (55%) and propafenone in 122 (45%). The first dose of PIP AAD was taken in a monitored setting in 167 (62%). Significant adverse events occurred in 7 patients (3%), 2 of whom had taken the dose in a monitored setting. Significant adverse events included unexplained syncope (1 of 7), symptomatic bradycardia/hypotension (4 of 7), and 1:1 atrial flutter (2 of 7). All occurred in patients taking 300 mg of flecainide (n = 4) or 600 mg of propafenone (n = 3). Electrical cardioversion was performed in 29 (11%) patients because of failure of the AAD to terminate AF. One patient required intravenous fluids and vasopressors for 2 hours because of persistent hypotension and bradycardia. Two patients required permanent pacemakers for bradycardia. The remaining patients required no intervention.

CONCLUSIONS

Our data support the current recommendation to initiate PIP AAD in a monitored setting because of rare significant adverse reactions that can require urgent intervention.

Для цитирования: Markman Timothy M, Jarrah Andrew A, Tian Ye, Mustin Evan, Guandalini Gustavo S, Lin David, Epstein Andrew E, Hyman Matthew C, Deo Rajat, Supple Gregory E, Arkles Jeffrey S, Dixit Sanjay, Schaller Robert D, Santangeli Pasquale, Nazarian Saman, Riley Michael, Callans David J, Marchlinski Francis E, Frankel David S. Safety of Pill-in-the-Pocket Class 1C Antiarrhythmic Drugs for Atrial Fibrillation.. JACC. Clinical electrophysiology. 2022. DOI: 10.1016/j.jacep.2022.07.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.