MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.bjps.2020.12.029

Медицинская библиотека · Journal of plastic, reconstructive & aesthetic surgery : JPRAS · 2020

Optimising the computerised adaptive test to reliably reduce the burden of administering the CLEFT-Q: A Monte Carlo simulation study.

Harrison Conrad J, Rodrigues Jeremy N, Furniss Dominic, Swan Marc C, Klassen Anne F, Wong Riff Karen W Y, Sidey-Gibbons Chris J

Письмо в редакциюПеревод в очереди

Аннотация

BACKGROUND

Computerised adaptive testing (CAT) has the potential to transform plastic surgery outcome measurement by making patient-reported outcome measures (PROMs) shorter, individualised and more accurate than pen-and-paper questionnaires.

OBJECTIVES

This paper reports the results of two optimisation studies for the CLEFT-Q CAT, a CAT intended for use in the field of cleft lip and/or palate. Specifically, we aimed to identify the optimal score estimation and item selection methods for using this CAT in clinical practice. These represent two major components of any CAT algorithm.

METHOD: Monte Carlo simulations were performed using simulated data in the R statistical computing environment and incorporated a range of score estimation and item selection techniques. The performance and accuracy of the CAT was assessed by mean items administered, correlation between CAT scores and paired linear assessment scores, and the root mean squared deviation (RMSD) of these score pairs.

RESULTS

The accuracy of the CLEFT-Q CAT was not significantly affected by the choice of score estimation or item selection method. Sub-scales which originally contain more items were amenable to greater item reduction with CAT.

CONCLUSION

This study shows that score estimation and item selection methods that need minimal processing power can be used in the CLEFT-Q CAT without compromising accuracy. This means that the CLEFT-Q CAT could be administered quickly and efficiently with basic hardware demands. We recommend the use of less computationally intensive techniques in future CLEFT-Q CAT studies.

Для цитирования: Harrison Conrad J, Rodrigues Jeremy N, Furniss Dominic, Swan Marc C, Klassen Anne F, Wong Riff Karen W Y, Sidey-Gibbons Chris J. Optimising the computerised adaptive test to reliably reduce the burden of administering the CLEFT-Q: A Monte Carlo simulation study.. Journal of plastic, reconstructive & aesthetic surgery : JPRAS. 2020. DOI: 10.1016/j.bjps.2020.12.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.