If we should remove internal fixation devices for rib fractures?

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Li Yang, Jiang Kaile, Zhao Tiancheng, Guo Xiang, Liu Kaibin, Zhao Yonghong

Аннотация

BACKGROUND: Internal fixation for rib fractures has been widely carried out worldwide, and its surgical efficacy has been recognized. However, there is still controversy about whether implant materials need to be removed. At present, the research on this topic is still lacking at home and abroad. Therefore, in this study, the patients undergoing removal of internal fixation for rib fractures in our department within one year were followed up, to statistically analyze implant-related complications, postoperative complications and postoperative remission rate.

METHODS: A retrospective analysis was conducted on 143 patients undergoing removal of internal fixation for rib fractures from 2020 to 2021 in our center. The implant-related complications, postoperative complications and postoperative remission rate of patients with internal fixation were analyzed.

RESULTS: In this study, a total of 143 patients underwent removal of internal fixation, among which 73 suffered from preoperative implant-related complications (foreign-body sensation, pain, wound numbness, sense of tightness, screw slippage, chest tightness, implant rejection), and 70 had no post operative discomfort but asked for removal of internal fixation. The average interval between rib fixation and removal was 17 ± 9.00 (months), and the average number of removed materials was 5.29 ± 2.42. Postoperative complications included wound infection (n = 1) and pulmonary embolism (n = 1). of the 73 patients with preoperative implant-related complications, the mean postoperative remission rate was 82%. Among the 70 patients without preoperative discomfort, the proportion of discomforts after removal was 10%. No perioperative death occurred.

CONCLUSION: For patients with internal fixation for rib fractures, removal of internal fixation can be considered in the case of implant-related complications after surgery. The corresponding symptoms can be relieved after removal. The removal presents low complication rate, and high safety and reliability. For patients without obvious symptoms, it is safe to retain the internal fixation in the body. For the asymptomatic patients who ask for removal of internal fixation, the possible risk of complications should be fully informed before removal.