MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3760/cma.j.issn.1003-9406.2017.02.005

Медицинская библиотека · Zhonghua yi xue yi chuan xue za zhi = Zhonghua yixue yichuanxue zazhi = Chinese journal of medical genetics · 2017

[Analysis of genome-wide copy number variations among fetuses with abnormalities detected by prenatal ultrasouography].

Wu Ke, Tang Shaohua, Chen Chong, Li Huanzheng, Zhou Lili, Lyu Jianxin

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To explore the genetic etiology of fetal abnormalities detected by prenatal ultrasound through single nucleotide polymorphism (SNP array) analysis.

METHODS

Two hundred and eight fetuses were tested with SNP array and conventional karyotyping. Complex copy number variations (CNVs) were verified with fluorescence in situ hybridization (FISH), multiplex ligation-dependent probe amplification (MLPA) and quantitative fluorescence polymerase chain reaction (QF-PCR).

RESULTS

For the 208 cases, the diagnostic yields of conventional karyotping and SNP assay were 8.2%(17/208) and 13.9%(29/208), respectively. For fetuses with malformations of the cardiovascular system, central nervous system or multiple systems, pathogenic CNVs was detected in 4.6% (8/174), 2.3%(4/174), and 1.1% (2/174) of all fetuses, respectively. No pathogenic CNVs was detected among those with abnormalities of the renal system, digestive system, skeletal system, facial dysmorphism or respiratory system.

CONCLUSION

CNVs are significantly related with birth defects. Compared with conventional karyotyping, SNP array is a better platform for CNVs detection and can provide more clues for genetic counseling, recurrence risk assessment and prenatal diagnosis.

Для цитирования: Wu Ke, Tang Shaohua, Chen Chong, Li Huanzheng, Zhou Lili, Lyu Jianxin. [Analysis of genome-wide copy number variations among fetuses with abnormalities detected by prenatal ultrasouography].. Zhonghua yi xue yi chuan xue za zhi = Zhonghua yixue yichuanxue zazhi = Chinese journal of medical genetics. 2017. DOI: 10.3760/cma.j.issn.1003-9406.2017.02.005.