m+Medelevator.RU
← Поиск публикаций
Journal of the mechanical behavior of biomedical materials · 2024

Three-axis load analysis of high-speed handpiece on dental training teeth and computer-aided design/computer-aided manufacturing blocks.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Lee Bora, Hwang Juyeon, Lim Jung-Hwa, Kim Jong-Eun, Shim June-Sung, Shin Yooseok

Аннотация

This study aimed to evaluate and compare the mechanical properties of dental training teeth with subtractive and additive computer-aided design/computer-aided manufacturing (CAD/CAM) materials used to fabricate dental simulation models. Therefore, the three-axis load generated during cutting movements, including drilling and milling performed using a dental handpiece, was measured and compared. The samples were cut vertically downward by 1.5 mm, horizontally by 6 mm, and vertically upward at a constant speed (1 mm/s), while the rotational speed of the bur was maintained at 200,000 rotations per minute. A three-axis load cell was used to measure the X-, Y-, and Z-axis loads on the specimen. The median value of the X-, Y-, and Z-axis measurements and the resultant load during the vertical-downward, horizontal, and vertical-upward movements were compared using a one-way analysis of variance and Tukey's post hoc test. For vertical downward movement, the drilling force of the dental training teeth was lower than that of Vita Enamic® and similar to that of Lava™ Ultimate. In contrast to subtractive CAD/CAM blocks, the drilling force of the dental training teeth was higher than that of 3D-printed resin blocks. Regarding horizontal movement, the milling force of dental training teeth was lower than that of Vita Enamic®. In contrast, the milling force of Nissin was similar to that of Lava™ Ultimate, while that of Frasaco was lower. Furthermore, compared to additive CAD/CAM blocks, the milling force of the dental training teeth was higher than that of 3D-printed resin blocks. Regarding vertical upward movement, the resultant loads of dental training teeth was lower than that of Vita Enamic®. Similarly, the resultant load of Nissin was similar to that of Lava™ Ultimate, while that of Frasaco was lower. Additionally, compared to additive CAD/CAM blocks, the resultant loads of the dental training teeth were similar to those of the 3D-printed resin blocks.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты