OBJECTIVE

To determine the efficacy of wiping the nasal atomizer tip with 70% isopropanol versus using single-use plastic atomizer tip guards in preventing cross-contamination.

STUDY

DESIGN

Single-center, prospective, partially blinded, alternating double-arm trial.

SETTING

Specialty-specific otolaryngology emergency room.

METHODS

Thirty-four consecutive patients who presented to an emergency room received nasal anesthetic with a Venturi atomizer. The atomizers for one half of patients were cleaned with an isopropyl alcohol pad immediately after use (group A). The atomizers for the other half were used with a sterile tip cover in place (group B). The effectiveness of 2 different methods in preventing contamination of the atomizer tip was compared.

RESULTS

One of the 17 atomizers from group A was contaminated(5.9%); 15 of the 17 atomizers from group B were contaminated(88.2%). This represents a difference of 82.3%, ora risk ratio of 15:1 against the use of nasal tip guards (P =.000002).

CONCLUSIONS

Venturi atomizer tips frequently become contaminated despite the use of a sterile tip cover. This happens at a dramatically decreased rate with the use of isopropyl alcohol for cleaning. Clinical significance of this contamination is uncertain.

Для цитирования: Kieff David, Fink Daniel. Decontamination of nasal atomizer tips: alcohol versus guards.. Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery. 2011. DOI: 10.1177/0194599811404318.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.