OBJECTIVE

To describe a focused transthoracic echocardiography (FoTE) curriculum for advanced practice providers (APPs) for echocardiography-driven diagnosis of shock in critically ill patients.

METHODS

Twelve APPs in 4 intensive care units at an academic medical center received didactic sessions on FoTE, including 1-on-1 proctorship with a registered cardiac sonographer. For a period of 6 months the trainees performed individual studies, then they performed FoTE examinations on critically ill patients; their diagnoses were compared with those of experienced intensivists for the same patients.

RESULTS

After 6 months of multiple steps of training, APPs could acquire good echocardiographic views, achieving a good inter-rater agreement (Cohen's κ of 0.745 [95% CI, 0.385-1.0; P < .01]) in the diagnosis of shock when compared to experienced intensivists.

CONCLUSIONS

Structured FoTE curriculum enables APPs to have reasonably good diagnostic concordance with intensivists in an echocardiography-driven diagnosis of shock in critically ill patients.

Для цитирования: Diaz-Gomez Jose L, Grek Ami A, Venegas-Borsellino Carla P, Chirila Andreea C, Builes Angela M, Ratzlaff Robert A. Focused transthoracic echocardiography curriculum for advanced practice providers assures good concordance with intensivists at echocardiography.. Heart & lung : the journal of critical care. 2018. DOI: 10.1016/j.hrtlng.2018.05.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.