MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1378/chest.108.4.982

Медицинская библиотека · Chest · 1995

A modified Abrams needle biopsy technique.

Kirsch C M, Kroe D M, Jensen W A, Kagawa F T, Wehner J H, Campagna A C

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

OBJECTIVE

To compare the diagnostic sensitivity of a modified Abrams needle pleural biopsy technique (A1) with the standard Abrams (A2) and Cope needle biopsy methods. The modified Abrams pleural biopsy technique consisted of suctioning each tissue sample into a syringe without removing the needle completely from the chest until the completion of the entire procedure. Both the standard Abrams and Cope needle techniques required needle removal from the chest after each pleural biopsy.

DESIGN

Retrospective chart analysis.

SETTING

Community teaching hospital affiliated with Stanford University.

PATIENTS: Forty-seven patients (30 men and 17 women) with a mean age 44.5 years (range, 19 to 81 years) who were referred to a pulmonary consultation service for pleural biopsy.

INTERVENTIONS: Two of us (C. M. K. and F. T. K.) used the modified Abrams technique and two of us (W. A. J. and A. C. C.) used the standard Abrams technique. The Cope needle was used as originally described.

MEASUREMENTS: We recorded the type of pleural biopsy needle and technique used in each patient. Biopsy specimen diameter and number of tissue samples obtained, final diagnoses, and complications were recorded.

RESULTS

The diagnostic sensitivity for tuberculous pleurisy was 82% for the modified Abrams method, 71% for the standard Abrams method, and 88% for the standard Cope technique (p > or = 0.3). There was no difference in size of tissue sample obtained (A1 vs A2), number of biopsies, or complications among the three methods of pleural biopsy.

CONCLUSIONS

The modified method of Abrams needle biopsy demonstrates a diagnostic sensitivity for pleural tuberculosis (82%) that is equivalent to that for the standard Abrams or Cope methods.

Для цитирования: Kirsch C M, Kroe D M, Jensen W A, Kagawa F T, Wehner J H, Campagna A C. A modified Abrams needle biopsy technique.. Chest. 1995. DOI: 10.1378/chest.108.4.982.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.