Медицинская библиотека · Acta orthopaedica Belgica · 2016

360° fixation with modern instrumentations of segment separation cervical spine injury in a 23-month-old.

Kovari V Zs, Vajda J, Veres R

Клинический случайСтатьяПеревод в очереди

Аннотация

In this case report clinical and technical lessons including seven years follow up learned from a flexion-distraction, highly unstable cervical spine injury causing a complete separation of C6-7 cervical segment with tetraparesis in a 23-month-old boy, are presented. To our knowledge this is the only documented case in medical literature where adult size implants (cage, plate and lateral mass screw-rod system) were utilized for cervical combined anterior and posterior internal fixation in a child under the age of two years without implant-size related problems. Seven years after the injury the child attends elementary school, can operate a wheelchair manually, and can eat and write. Computed tomography control showed no failure of the hardware and fusion was later observed in the intervertebral space of the stabilized cervical segment, however adjacent segment syndrome occurred without deterioration of the patient's status. The decision on the mode of realignment and fixation to be made in such a case was difficult because there is no standard procedure for infants.

Для цитирования: Kovari V Zs, Vajda J, Veres R. 360° fixation with modern instrumentations of segment separation cervical spine injury in a 23-month-old.. Acta orthopaedica Belgica. 2016.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.