MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.juro.2010.04.003

Медицинская библиотека · The Journal of urology · 2010

Prospective evaluation of a single incision sling for stress urinary incontinence.

Kennelly Michael J, Moore Robert, Nguyen John N, Lukban James C, Siegel Steven

СтатьяМногоцентровое исследованиеПеревод в очереди

Аннотация

PURPOSE: We report 12-month outcomes of the MiniArc single incision sling for stress urinary incontinence in women.

MATERIALS AND

METHODS

We performed a multicenter, prospective, single arm institutional review board/ethics committee approved study evaluating the effectiveness of the MiniArc sling after implantation via qualitative (Urogenital Distress Inventory-Short Form and Incontinence Impact Questionnaire-Short Form) and quantitative (1-hour pad weight test and cough stress test) measurements. Secondary outcome measures included procedural variables (procedure time and estimated blood loss), length of stay, perioperative complications, Wong-Baker Faces Pain Scale and adverse events.

RESULTS

A total of 188 women with a mean age of 51.1 +/- 10.6 years (median 50.4, range 25.9 to 79.6) were enrolled in the study. At 1 year 157 patients were available for analysis. Mean procedure time, estimated blood loss and length of hospital stay were 11.0 +/- 6.7 minutes (median 10, range 2 to 55), 41.7 +/- 47.0 ml (median 25, range 0 to 250) and 9.5 +/- 14.1 hours (median 3.2, range 0.5 to 77.2), respectively. At discharge from hospital the mean Wong-Baker pain score was 1.3 +/- 2.0 (range 0.0 to 10.0). Of the patients 90.6% had a negative cough stress test and 84.5% had a 1-hour pad weight test less than 1 gm at 12 months. Median Urogenital Distress Inventory-Short Form and Incontinence Impact Questionnaire-Short Form scores showed a statistically significant decrease (p <0.001). Adverse events included urinary tract infection (4.3%), constipation (3.7%), temporary urinary retention (3.2%), dyspareunia (2.1%) and vaginal extrusion (1.6%).

CONCLUSIONS

The MiniArc single incision sling is a safe and effective first line surgical procedure for the treatment of female stress urinary incontinence. It demonstrated excellent patient tolerability with minimal pain, early return to normal activity and low morbidity. In addition to sustained efficacy outcomes at 12 months patients treated with the MiniArc experienced a significant improvement in quality of life.

Для цитирования: Kennelly Michael J, Moore Robert, Nguyen John N, Lukban James C, Siegel Steven. Prospective evaluation of a single incision sling for stress urinary incontinence.. The Journal of urology. 2010. DOI: 10.1016/j.juro.2010.04.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.