MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/adhm.201800695

Медицинская библиотека · Advanced healthcare materials · 2018

Multiplexed In Vivo Imaging Using Size-Controlled Quantum Dots in the Second Near-Infrared Window.

Jeong Sanghwa, Jung Yebin, Bok Seoyeon, Ryu Yeon-Mi, Lee Sumin, Kim Young-Eun, Song Jaejung, Kim Miyeon, Kim Sang-Yeob, Ahn G-One, Kim Sungjee

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PbS/CdS core/shell quantum dots (QDs) that emit at the second near-infrared (NIR-II, 1000-1700 nm) window are synthesized. The PbS seed size and CdS shell thicknesses are carefully controlled to produce bright and narrow fluorescence that are suitable for multiplexing. A polymer encapsulation yields polymer-encapsulated NIR-II QDs (PQDs), which provides the QDs with long-term fluorescence stability over a week in biological media. Exploiting the simple bioconjugation capability of PQDs, folic acids are conjugated to PQDs that can efficiently label folate receptor overexpressing cell lines. The PQDs afford multiplexed and nearly real-time longitudinal whole-body in vivo imaging. Two NIR-II QD probes are prepared: folic acid-conjugated PQDs (FA-PQDs) emitting at 1280 nm and unconjugated PQDs emitting at 1080 nm. The two PQDs are engineered to have compact and similar hydrodynamic sizes. A mixture of the folic acid-conjugated PQD and unconjugated PQDs is injected intravenously into a tumor-xenografted mouse, and the signals from them are monitored. This NIR-II whole-body imaging with the two PQDs provides precise evaluation of the active ligand-assisted tumor-targeting capability of the FA-PQD probe because the hydrodynamic size control of the two PQDs effectively eliminates effects from the size-dependent accumulations by permeations and retentions in tumors.

Для цитирования: Jeong Sanghwa, Jung Yebin, Bok Seoyeon, Ryu Yeon-Mi, Lee Sumin, Kim Young-Eun, Song Jaejung, Kim Miyeon, Kim Sang-Yeob, Ahn G-One, Kim Sungjee. Multiplexed In Vivo Imaging Using Size-Controlled Quantum Dots in the Second Near-Infrared Window.. Advanced healthcare materials. 2018. DOI: 10.1002/adhm.201800695.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.