MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.talanta.2013.08.044

Медицинская библиотека · Talanta · 2013

An organic thin film photodiode as a portable photodetector for the detection of alkylphenol polyethoxylates by a flow fluorescence-immunoassay on magnetic microbeads in a microchannel.

Ishimatsu Ryoichi, Naruse Azusa, Liu Rong, Nakano Koji, Yahiro Masayuki, Adachi Chihaya, Imato Toshihiko

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

An organic thin film photodiode (OPD) was successfully employed as a portable photodetector in a competitive enzyme-linked immunosorbent assay (ELISA) of a class of nonionic surfactants, namely alkylphenol polyethoxylates (APnEOs) which are an environmental pollutant. Microbeads that were chemically immobilized with an anti-APnEOs antibody were used in the assay. The OPD consisted of a layer of copper phthalocyanine (CuPc), C60 and a second layer of bathocuproine (BCP) with a bulk heterojunction composed of CuPc and C60 prepared by a vapor deposition method on an indium-tin oxide coated glass substrate. The OPD showed an incident photon-current efficiency (IPCE) of approximately 19% for light at a wavelength of 585 nm. This relatively high IPCE at 585 nm makes it suitable for detecting the fluorescence of resorufin (λem=585 nm), the product of the competitive ELISA, produced through the enzymatic reaction of Amplex Red with horseradish peroxidase (HRP) and H2O2. A fluorometric detector was assembled on a microchip by combining the fabricated OPD and a commercial LED as a photodetector and a light source, respectively. The photocurrent of the OPD due to the fluorescence of resorufin was proportional to the concentration of resorufin in the concentration range from 0 to 8 μM. When the fabricated OPD was used as a portable photodetector, the competitive ELISA of APnEOs using HRP labeled APnEOs (HRP-APnEOs) was performed on magnetic microbeads on which surface an anti-APnEOs antibody had been immobilized. A typical sigmoidal calibration curve was obtained and the data were in good agreement with a numerical simulation, where the photocurrent of the OPD was plotted against the concentration of APnEOs, determined via the competitive ELISA. The detection limit of the immunoassay for APnEOs was approximately 2 and 4 ppb in batch and flow system, respectively.

Для цитирования: Ishimatsu Ryoichi, Naruse Azusa, Liu Rong, Nakano Koji, Yahiro Masayuki, Adachi Chihaya, Imato Toshihiko. An organic thin film photodiode as a portable photodetector for the detection of alkylphenol polyethoxylates by a flow fluorescence-immunoassay on magnetic microbeads in a microchannel.. Talanta. 2013. DOI: 10.1016/j.talanta.2013.08.044.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.