MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s41747-026-00738-7

Медицинская библиотека · European radiology experimental · 2026

Who labels best? Radiologists, rules, or large language models for CT reports on pulmonary embolism.

Fink Matthias A, Bischoff Arved, Atsiatorme Edem, Kremer Alexander, Kroschke Jonas, Moll Martin, Stein Patrick, Riebl Veronika, Leichenich Timo, Kauczor Hans-Ulrich, Schlamp Kai

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare open-weight and proprietary large language models (LLMs), a rule-based extractor (RBE) and radiologists for labelling pulmonary embolism CT reports, and to test whether a hybrid RBE-LLM workflow improves labelling performance.

MATERIALS AND

METHODS

This single-centre retrospective study included structured CT reports from October 2021 to March 2025. Three labelling pipelines were evaluated: an RBE; a model-agnostic LLM extractor (18 open-weight, four GPT-4 variants); and a hybrid pipeline routing only RBE failures to an LLM. Ground truth was defined at the report-text level by deterministic schema matching for initially RBE-valid fields and blinded adjudication of RBE-invalid fields by two attending radiologists. Eight radiologists provided a human baseline. Outcomes included F1 scores, accuracy, LLM-based salvage of RBE failures, and labelling time.

RESULTS

In total, 2,923 reports from 2,923 patients (mean age 66 ± 17 years; 1,465 women) were included. Falcon3-10b and GPT-4.1-mini achieved similar item-level performance (F1 0.98 [95% CI, 0.97-0.98] for both; p = 0.70) and both exceeded the RBE (F1 0.81 [95% CI, 0.80-0.82]; p < 0.001). Salvage of RBE failures was comparable between open-weight and proprietary models (88.1% vs 91.9%; p = 0.12). The hybrid RBE-LLM workflow achieved 99.8% accuracy and F1 0.99 (0.98-0.99), exceeding both the RBE and pooled radiologists (F1 0.92 [95% CI, 0.90-0.93]; all p < 0.001).

CONCLUSION

Schema-constrained open-weight and proprietary LLMs exceeded rule-based extraction and, at the upper end of performance, matched a pooled radiologist label-transfer baseline. A rules-first, targeted LLM workflow enabled near-perfect extraction from finalised structured pulmonary embolism CT reports.

RELEVANCE STATEMENT: A rules-first LLM workflow can automate high-fidelity extraction of structured CT findings from finalised radiology reports, enabling scalable, auditable, and more consistent cohort curation for clinical research, registries, and quality improvement.

KEY POINTS: A hybrid rules-first workflow combining a rule-based extractor (RBE) with targeted large language model (LLM) salvage achieved the highest overall performance for labelling of pulmonary embolism CT reports (F1, 0.99; accuracy, 99.8%). The top standalone open-weight and proprietary LLMs (Falcon3-10b and GPT-4.1-mini) both exceeded the RBE and, at the upper end of performance, matched a pooled radiologist label-transfer baseline. The hybrid workflow reduced cohort-curation time from 32.2 h for radiologists to 1.0 h while reducing LLM calls by 85.6%, because the LLM was only triggered for rule-failed fields.

Для цитирования: Fink Matthias A, Bischoff Arved, Atsiatorme Edem, Kremer Alexander, Kroschke Jonas, Moll Martin, Stein Patrick, Riebl Veronika, Leichenich Timo, Kauczor Hans-Ulrich, Schlamp Kai. Who labels best? Radiologists, rules, or large language models for CT reports on pulmonary embolism.. European radiology experimental. 2026. DOI: 10.1186/s41747-026-00738-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.