Rocha Ferreira Graziela Santos, de Almeida Juliano Pinheiro, Landoni Giovanni, Vincent Jean Louis, Fominskiy Evgeny, Gomes Galas Filomena Regina Barbosa, Gaiotto Fabio A, Dallan Luís Oliveira, Franco Rafael Alves, Lisboa Luiz Augusto, Palma Dallan Luis Roberto, Fukushima Julia Tizue, Rizk Stephanie Itala, Park Clarice Lee, Strabelli Tânia Mara, Gelas Lage Silvia Helena, Camara Ligia, Zeferino Suely, Jardim Jaquelline, Calvo Arita Elisandra Cristina Trevisan, Caldas Ribeiro Juliana, Ayub-Ferreira Silvia Moreira, Costa Auler Jose Otavio, Filho Roberto Kalil, Jatene Fabio Biscegli, Hajjar Ludhmila Abrahao

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

The aim of this study was to evaluate the efficacy of perioperative intra-aortic balloon pump use in high-risk cardiac surgery patients.

DESIGN

A single-center randomized controlled trial and a meta-analysis of randomized controlled trials.

SETTING

Heart Institute of São Paulo University.

PATIENTS: High-risk patients undergoing elective coronary artery bypass surgery.

INTERVENTION: Patients were randomized to receive preskin incision intra-aortic balloon pump insertion after anesthesia induction versus no intra-aortic balloon pump use.

MEASUREMENTS AND MAIN

RESULTS

The primary outcome was a composite endpoint of 30-day mortality and major morbidity (cardiogenic shock, stroke, acute renal failure, mediastinitis, prolonged mechanical ventilation, and a need for reoperation). A total of 181 patients (mean [SD] age 65.4 [9.4] yr; 32% female) were randomized. The primary outcome was observed in 43 patients (47.8%) in the intra-aortic balloon pump group and 42 patients (46.2%) in the control group (p = 0.46). The median duration of inotrope use (51 hr [interquartile range, 32-94 hr] vs 39 hr [interquartile range, 25-66 hr]; p = 0.007) and the ICU length of stay (5 d [interquartile range, 3-8 d] vs 4 d [interquartile range, 3-6 d]; p = 0.035) were longer in the intra-aortic balloon pump group than in the control group. A meta-analysis of 11 randomized controlled trials confirmed a lack of survival improvement in high-risk cardiac surgery patients with perioperative intra-aortic balloon pump use.

CONCLUSIONS

In high-risk patients undergoing cardiac surgery, the perioperative use of an intra-aortic balloon pump did not reduce the occurrence of a composite outcome of 30-day mortality and major complications compared with usual care alone.

Для цитирования: Rocha Ferreira Graziela Santos, de Almeida Juliano Pinheiro, Landoni Giovanni, Vincent Jean Louis, Fominskiy Evgeny, Gomes Galas Filomena Regina Barbosa, Gaiotto Fabio A, Dallan Luís Oliveira, Franco Rafael Alves, Lisboa Luiz Augusto, Palma Dallan Luis Roberto, Fukushima Julia Tizue, Rizk Stephanie Itala, Park Clarice Lee, Strabelli Tânia Mara, Gelas Lage Silvia Helena, Camara Ligia, Zeferino Suely, Jardim Jaquelline, Calvo Arita Elisandra Cristina Trevisan, Caldas Ribeiro Juliana, Ayub-Ferreira Silvia Moreira, Costa Auler Jose Otavio, Filho Roberto Kalil, Jatene Fabio Biscegli, Hajjar Ludhmila Abrahao. Effect of a Perioperative Intra-Aortic Balloon Pump in High-Risk Cardiac Surgery Patients: A Randomized Clinical Trial.. Critical care medicine. 2018. DOI: 10.1097/ccm.0000000000003185.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.