MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ehf2.13367

Медицинская библиотека · ESC heart failure · 2021

Feasibility of remote speech analysis in evaluation of dynamic fluid overload in heart failure patients undergoing haemodialysis treatment.

Amir Offer, Anker Stefan D, Gork Ittamar, Abraham William T, Pinney Sean P, Burkhoff Daniel, Shallom Ilan D, Haviv Ronit, Edelman Elazer R, Lotan Chaim

СтатьяНаблюдательное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

AIMS: This study aimed to assess the ability of a voice analysis application to discriminate between wet and dry states in chronic heart failure (CHF) patients undergoing regular scheduled haemodialysis treatment due to volume overload as a result of their chronic renal failure.

METHODS AND

RESULTS

In this single-centre, observational study, five patients with CHF, peripheral oedema of ≥2, and pulmonary congestion-related dyspnoea, undergoing haemodialysis three times per week, recorded five sentences into a standard smartphone/tablet before and after haemodialysis. Recordings were provided that same noon/early evening and the next morning and evening. Patient weight was measured at the hospital before and after each haemodialysis session. Recordings were analysed by a smartphone application (app) algorithm, to compare speech measures (SMs) of utterances collected over time. On average, patients provided recordings throughout 25.8 ± 3.9 dialysis treatment cycles, resulting in a total of 472 recordings. Weight changes of 1.95 ± 0.64 kg were documented during cycles. Median baseline SM prior to dialysis was 0.87 ± 0.17, and rose to 1.07 ± 0.15 following the end of the dialysis session, at noon (P = 0.0355), and remained at a similar level until the following morning (P = 0.007). By the evening of the day following dialysis, SMs returned to baseline levels (0.88 ± 0.19). Changes in patient weight immediately after dialysis positively correlated with SM changes, with the strongest correlation measured the evening of the dialysis day [slope: -0.40 ± 0.15 (95% confidence interval: -0.71 to -0.10), P = 0.0096].

CONCLUSIONS

The fluid-controlled haemodialysis model demonstrated the ability of the app algorithm to identify cyclic changes in SMs, which reflected bodily fluid levels. The voice analysis platform bears considerable potential as a harbinger of impending fluid overload in a range of clinical scenarios, which will enhance monitoring and triage efforts, ultimately optimizing remote CHF management.

Для цитирования: Amir Offer, Anker Stefan D, Gork Ittamar, Abraham William T, Pinney Sean P, Burkhoff Daniel, Shallom Ilan D, Haviv Ronit, Edelman Elazer R, Lotan Chaim. Feasibility of remote speech analysis in evaluation of dynamic fluid overload in heart failure patients undergoing haemodialysis treatment.. ESC heart failure. 2021. DOI: 10.1002/ehf2.13367.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.