MedElevator Войти в исследования
← Поиск публикаций

DOI 10.23736/s2724-6051.24.05706-9

Медицинская библиотека · Minerva urology and nephrology · 2024

Prospective randomized multicenter study to evaluate holmium vs. new thulium fiber laser for prostate enucleation.

Romero Otero Javier, Justo Quintas Juan, García Gómez Borja, Manfredi Celeste, Sopeña Sutil Raquel, Peña Vallejo Elena, Lista Mateos Fernando, Bozzini Giorgio, Rodríguez Antolín Alfredo, García Rojo Esther

СтатьяМногоцентровое исследованиеРандомизированное исследованиеСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Benign prostatic hyperplasia (BPH) commonly causes lower urinary tract symptoms (LUTS) in men. Holmium (HoLEP) and thulium (ThuLEP) laser enucleation are established techniques for BPH treatment. Thulium fiber laser (TFL) for prostate enucleation (ThuFLEP) shows promising outcomes.

METHODS

A prospective randomized multicenter study was conducted. Patients with BPH and LUTS unresponsive to medical therapy were enrolled. Preoperative, surgical, perioperative and postoperative data were recorded with follow-up at 3 and 6 months. The primary outcome was functional improvement, and the secondary outcome was safety in terms of complications.

RESULTS

Two hundred patients were included (HoLEP 100, ThuFLEP 100). No significant baseline difference was found between groups. At 3 and 6 months we found statistically significant improvements from baseline for both HoLEP and ThuFLEP in efficacy: International Prostatic Symptoms Score (IPSS), IPSS-Quality of Life (QoL), maximum urinary flow rate (Q<inf>max</inf>), and post-void residual volume (PVR; P<0.05). At 6 months, mean±SD IPSS, IPSS-QoL, Q<inf>max</inf>, and PVR for HoLEP vs. ThuFLEP were 5.8±4.9 vs. 4.8±5.0 points (P=0.57), 1.6±1.4 vs. 0.7±1.1 points (P=0.09), 29.9±12.5 vs. 29.6±8.0 mL/s (P=0.8), and 16.3±17.7 vs. 15.5±13.4 mL (P=0.92), respectively. No intraoperative complication was recorded. No Clavien-Dindo ≥III complications occurred during hospitalization. After 6 months, 8 (8%) and 6 (6%) patients reported mild stress urinary incontinence in HoLEP and ThuFLEP groups, respectively (P=0.24). Urethral stenosis was observed in 3 men (3%) in the HoLEP group and 1 subject (1%) in the ThuFLEP group (P=0.72).

CONCLUSIONS

HoLEP and ThuFLEP are effective and safe for BPH treatment, with comparable functional outcomes and complication rates at 6 months. Further research is needed to confirm these findings.

Для цитирования: Romero Otero Javier, Justo Quintas Juan, García Gómez Borja, Manfredi Celeste, Sopeña Sutil Raquel, Peña Vallejo Elena, Lista Mateos Fernando, Bozzini Giorgio, Rodríguez Antolín Alfredo, García Rojo Esther. Prospective randomized multicenter study to evaluate holmium vs. new thulium fiber laser for prostate enucleation.. Minerva urology and nephrology. 2024. DOI: 10.23736/s2724-6051.24.05706-9.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.