MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/00016357.2011.572287

Медицинская библиотека · Acta odontologica Scandinavica · 2011

Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.

Merıç Gökçe, Erkmen Erkan, Kurt Ahmet, Eser Atilim, özden Ahmet Utku

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of the study was to compare the effects of two distinct collar geometries of implants on stress distribution in the bone around the implants supporting cantilever fixed partial dentures (CFPDs) as well as in the implant-abutment complex and superstructures.

MATERIALS AND

METHODS

The three-dimensional finite element method was selected to evaluate the stress distribution. CFPDs which was supported by microthread collar structured (MCS) and non-microthread collar structured (NMCS) implants was modeled; 300 N vertical, 150 N oblique and 60 N horizontal forces were applied to the models separately. The stress values in the bone, implant-abutment complex and superstructures were calculated.

RESULTS

In the MCS model, higher stresses were located in the cortical bone and implant-abutment complex in the case of vertical load while decreased stresses in cortical bone and implant-abutment complex were noted within horizontal and oblique loading. In the case of vertical load, decreased stresses have been noted in cancellous bone and framework. Upon horizontal and oblique loading, a MCS model had higher stress in cancellous bone and framework than the NMCS model. Higher von Mises stresses have been noted in veneering material for NMCS models.

CONCLUSION

It has been concluded that stress distribution in implant-supported CFPDs correlated with the macro design of the implant collar and the direction of applied force.

Для цитирования: Merıç Gökçe, Erkmen Erkan, Kurt Ahmet, Eser Atilim, özden Ahmet Utku. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.. Acta odontologica Scandinavica. 2011. DOI: 10.3109/00016357.2011.572287.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.