Arachnoid Welding-A Simple and Economical Method of Arachnoid Closure to Prevent Cerebrospinal Fluid Leak.

Ruparelia Jigish, Kumar V R Roopesh

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND

Collection of cerebrospinal fluid (CSF) in the subdural compartment is a major cause of postoperative morbidity, especially for posterior fossa surgeries. Arachnoid closure techniques, including suturing of the arachnoid and use of synthetic sealants, have been described in the literature. However, they are not always feasible or effective and have not been universally adopted.

METHODS

We describe the technique of arachnoid welding for a case of brainstem cavernoma. This is a simple, cost-effective, and easily reproducible technique using readily available bipolar cautery kept at a low-current setting. At the end of surgery, the arachnoid leaflets are closely approximated, and bipolar cautery is used to seal the edges together. An illustrative video shows the technical nuances of this procedure. This technique can also be applied for arachnoid closure at other cranial and spinal sites.

RESULTS

Arachnoid closure can act as an effective natural barrier to keep CSF in its physiological subarachnoid compartment. It provides an additional barrier to prevent CSF leak. It also prevents morbidity associated with adhesions and arachnoiditis. Proper closure of arachnoid makes durotomy during repeat surgery much easier and avoids injury to the underlying pia. A brief review of related literature shows the benefits of closing the arachnoid before dural closure and the different techniques that have been described so far.

CONCLUSIONS

The arachnoid welding technique has a wide application, is easy to learn, and can be used especially for posterior fossa surgeries in which rates of CSF leak are the highest.

Для цитирования: Ruparelia Jigish, Kumar V R Roopesh. Arachnoid Welding-A Simple and Economical Method of Arachnoid Closure to Prevent Cerebrospinal Fluid Leak.. World neurosurgery. 2023. DOI: 10.1016/j.wneu.2023.09.047.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.