MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1128/jcm.01870-20

Медицинская библиотека · Journal of clinical microbiology · 2021

Multicenter Evaluation of Ceftazidime-Avibactam Susceptibility Testing of Enterobacterales and Pseudomonas aeruginosa on the Vitek 2 System.

Humphries Romney, Campeau Shelley, Davis Thomas E, Nagaro Kristin J, LaBombardi Vincent J, Franklin Simone, Heimbach Lisa, Dwivedi Hari P

СтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

In this multisite study, Vitek 2 AST-Gram-Negative Ceftazidime/Avibactam test results for 1,073 isolates (866 Enterobacterales and 207 Pseudomonas aeruginosa) were compared to the Clinical and Laboratory Standards Institute (CLSI) broth microdilution (BMD) reference method. The results were analyzed for essential agreement (EA), category agreement (CA), major error rates, and very major error rates following FDA/ISO performance criteria using the FDA-recognized CLSI/EUCAST breakpoints (sensitive [S], ≤8/4 μg/ml; resistant [R], ≥16/4 μg/ml). The overall EA was 94.5% (1,014/1,073) and CA was 98.7% (1,059/1,073). No very major errors were reported. The major error rate was 1.4% (14/998). Out of 14 major errors, 9 were within EA. Based on the EA and lack of an intermediate category for ceftazidime-avibactam (CZA), the adjusted major error rate for FDA criteria was 0.5% (5/998). The performance for ISO criteria after error resolutions included EA of 94.5% (1,014/1,073), CA of 98.9% (1,061/1,073), major error of 1.2% (12/998), and no very major error. Vitek 2 met the ISO and FDA criteria of ≥95% reproducibility and ≥95% quality control (QC) results within acceptable ranges for QC organisms. Vitek 2 overall performance for Enterobacterales and P. aeruginosa met or exceeded the FDA and ISO performance criteria; thus, it is a reliable alternative to the BMD reference method for routine CZA susceptibility testing.

Для цитирования: Humphries Romney, Campeau Shelley, Davis Thomas E, Nagaro Kristin J, LaBombardi Vincent J, Franklin Simone, Heimbach Lisa, Dwivedi Hari P. Multicenter Evaluation of Ceftazidime-Avibactam Susceptibility Testing of Enterobacterales and Pseudomonas aeruginosa on the Vitek 2 System.. Journal of clinical microbiology. 2021. DOI: 10.1128/jcm.01870-20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление